Abstract
The dynamic hysteresis nonlinearity and various uncertainties of the piezoelectric positioning platform are critical factors limiting its high-precision applications. To address this, the dynamic characteristics of the piezoelectric positioning platform under various loads are identified based on the linearization of the Prandtl–Ishlinskii inverse model. The inverse compensation error and load disturbances are attributed to model uncertainties, which are modeled in the frequency domain. A μ-synthesis controller is designed to improve the tracking accuracy of the piezoelectric positioning platform under uncertainty disturbances. The experimental results of sine wave tracking indicate that with the μ-synthesis controller, the piezoelectric positioning platform achieves a relative error (RE) of less than 2.71% when unloaded. The RE is less than 6.03% for load disturbances of 100 g, 200 g, and 300 g, respectively. These results demonstrate that the designed controller meets the high-precision positioning performance requirements under various load disturbance conditions.
Funding Information
  • High performance antenna servo control system’s theory and methods (61933006)

This publication has 40 references indexed in Scilit: