Conversion of hemi into reverse shoulder arthroplasty: implant design limitations
- 4 November 2014
- journal article
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 134 (12) , 1683-1689
Abstract
Cranial migration of shoulder hemiarthroplasties due to rotator cuff insufficiency typically requires conversion into a reverse total shoulder arthroplasty. This study was conducted to analyze differences between the height and offset of six implants designed to enable conversion of a hemiarthroplasty into a reverse system. Anteroposterior radiographs of 40 shoulders were taken. An image analyzing software was used to simulate the implantation of the hemiprostheses. Then the implant was dissembled, leaving on the stem within the humeral shaft. Finally, the implantation of a reverse system was simulated using the stem in the same position. Values are reported as ∆-height and ∆-offset ± standard deviation. Significance was assumed for P < 0.05. The least decrease in height was determined for Implantcast with 11.6 ± 3.3 mm, followed by DePuy (16 ± 5.7 mm) and the greatest for Tornier with 33 ± 5.3 mm. No significant differences were found among Exactech, Mathys and Zimmer. The largest offset-deviation was calculated for DePuy (−21.7 ± 3.7 mm) and the smallest for Implantcast (−3.3 ± 2.8 mm) and Tornier (1.5 ± 5.7 mm). Due to the modular stem, the system of Implantcast can be converted in a reverse system with the least changes in height and offset. For the other manufacturers it does not seem possible to convert a hemiprosthesis to a reversed prosthesis without accepting additional tension of the deltoid muscle. Further experimental studies have to analyze the changes in deltoid abduction moments after conversion of a hemi- into a reversed prosthesis.Keywords
This publication has 19 references indexed in Scilit:
- Reverse Shoulder Arthroplasty – A Literature ReviewThe Open Orthopaedics Journal, 2013
- Functional outcome of hemiarthroplasty compared with reverse total shoulder arthroplasty in the treatment of rotator cuff tear arthropathyJournal of Shoulder and Elbow Surgery, 2012
- Reverse Total Shoulder Arthroplasty Improves Function in Cuff Tear ArthropathyClinical Orthopaedics and Related Research, 2011
- Total Shoulder ArthroplastyThe Open Orthopaedics Journal, 2011
- Anatomic and reverse shoulder prostheses in fracture sequelae of the humeral headActa Orthopaedica et Traumatologica Turcica, 2010
- Risk factors for revision after shoulder arthroplastyActa Orthopaedica, 2009
- Reverse Total Shoulder ArthroplastyJournal of Bone and Joint Surgery, 2007
- Radiologic Assessment of Reverse Shoulder ArthroplastyRadioGraphics, 2007
- Neer Award 2005: The Grammont reverse shoulder prosthesis: Results in cuff tear arthritis, fracture sequelae, and revision arthroplastyJournal of Shoulder and Elbow Surgery, 2006
- Evaluación clinicorradiológica en hemiartroplastia de hombroReumatología Clínica, 2005