We describe a simple, quick technique to construct a slipknot that can be snared around the haptic of an intraocular lens (IOL) during transscleral fixation of a posterior chamber IOL or repositioning of a dislocated IOL. An in vitro experiment showed that the time required for the slipknot method was significantly less than that for the traditional triple-knot method. An additional advantage is that the slipknot technique can be performed by a single surgeon using standard ophthalmic instrumentation. In addition, the slipknot is as secure as a triple knot.