Intrasaccular flow-diversion for treatment of intracranial aneurysms: the Woven EndoBridge
Authors:
- Laurent PierotLPLaurent Pierot
- Boris LubiczBLBoris Lubicz
- 21 March 2014
- journal article
- review article
- Published by Taylor & Francis in Expert Review of Medical Devices
- Vol. 11 (3) , 315-325
Abstract
Endovascular approach is now the first option for the treatment of most intracranial aneurysms (IA). However, remaining limitations are the suboptimal stability of aneurysm occlusion and the treatment of complex IA. The use of conventional and flow diverter stents has partially addressed these limitations. Nevertheless, as intraluminal devices, stents require aggressive antiplatelet therapy and are associated with higher thromboembolic (TE) complication rates. Intrasaccular flow disrupters (IFD) are newly developed braided-wire devices designed to achieve flow disruption at the neck without placing material in the parent vessel and without the need of antiplatelet therapy. First clinical series have shown promising anatomical and clinical results. Our purpose is to describe the available IFD and to review the literature about their efficacy, safety, limitations, and developments.Keywords
This publication has 51 references indexed in Scilit:
- Guidelines for the Management of Aneurysmal Subarachnoid HemorrhageStroke, 2012
- Results of Embolization Used as the First Treatment Choice in a Consecutive Nonselected Population of Ruptured Aneurysms: Clinical Results of the Clarity GDC StudyNeurosurgery, 2011
- Safety and Efficacy of Balloon Remodeling Technique during Endovascular Treatment of Intracranial Aneurysms: Critical Review of the LiteratureAmerican Journal of Neuroradiology, 2011
- Endovascular occlusion of intracranial wide-necked aneurysms with stenting (Neuroform) and coiling: mid-term and long-term resultsNeuroradiology, 2009
- Immediate Clinical Outcome of Patients Harboring Unruptured Intracranial Aneurysms Treated by Endovascular ApproachStroke, 2008
- Flow changes caused by the sequential placement of stents across the neck of sidewall cerebral aneurysmsJournal of Neurosurgery, 2005
- Stent-assisted coil embolization of intracranial wide-necked aneurysmsNeuroradiology, 2005
- International Subarachnoid Aneurysm Trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised trialThe Lancet, 2002
- Intravascular stent and endovascular coil placement for a ruptured fusiform aneurysm of the basilar arteryJournal of Neurosurgery, 1997
- Electrothrombosis of saccular aneurysms via endovascular approachJournal of Neurosurgery, 1991