Objectives To describe a new technique to obtain minimally invasive but efficient vertebral body (VB) reconstruction, augmentation, and stabilization in severe osteoporotic and neoplastic fractures, combining two pre-existing procedures. The implant of vertebral body stents (VBS) is followed by insertion of percutaneous, fenestrated, cement-augmented pedicular screws that act as anchors to the posterior elements for the cement/stent complex. The screws reduce the risk of stent mobilization in a non-intact VB cortical shell and bridge middle column and pedicular fractures. This procedure results in a 360° non-fusion form of vertebral internal fixation that may empower vertebral augmentation and potentially avoid corpectomy in challenging fractures. Procedure details This report provides step-by-step procedural details, rationale, and proposed indications for this procedure. The procedure is entirely percutaneous under fluoroscopic guidance. Through transpedicular trocars the VBS are inserted, balloon-expanded and implanted in the VB. Over k-wire exchange the transpedicular screws are inserted inside the lumen of the stents and cement is injected through the screws to augment the stents and fuse the screws to the stents. Applications This technique may find appropriate applications for the most severe osteoporotic fractures with large clefts, high-degree fragmentation and collapse, middle column and pedicular involvement, and in extensive neoplastic lytic lesions. Conclusions Stent-Screw-Assisted Internal Fixation (SAIF) might represent a minimally invasive option to obtain VB reconstruction and restoration of axial load capability in severe osteoporotic and neoplastic fractures, potentially obviating the need for more invasive surgical interventions in situations that would pose significant challenges to standard vertebroplasty or balloon kyphoplasty.Keywords
This publication has 23 references indexed in Scilit:
- Radiographic and safety details of vertebral body stenting: results from a multicenter chart reviewBMC Musculoskeletal Disorders, 2013
- Vertebral Body Stenting Versus Kyphoplasty for the Treatment of Osteoporotic Vertebral Compression FracturesJournal of Bone and Joint Surgery, 2013
- Surgical procedure and initial radiographic results of a new augmentation technique for vertebral compression fracturesEuropean Spine Journal, 2013
- Early results after vertebral body stenting for fractures of the anterior column of the thoracolumbar spineInjury, 2011
- Guidelines to Imaging Landmarks for Interventional Spine Procedures: Fluoroscopy and CT AnatomyNeurographics, 2011
- Vertebral body stenting: a new method for vertebral augmentation versus kyphoplastyEuropean Spine Journal, 2010
- Posterior decompression and stabilization, and surgical vertebroplasty with the vertebral body stenting for metastatic vertebral and epidural cauda equina compressionJournal of Surgical Oncology, 2010
- Treatment of Vertebral Tumor with Posterior Wall Defect Using Image-guided Radiofrequency Ablation Combined with Vertebroplasty: Preliminary Results in 12 PatientsJournal of Vascular and Interventional Radiology, 2007
- The Load Sharing Classification of Spine FracturesSpine, 1994
- Vertebral fracture assessment using a semiquantitative techniqueJournal of Bone and Mineral Research, 1993