Novel trans-septal approach using a Safe Sept J-shaped guidewire in difficult left atrial access during atrial fibrillation ablation
Open Access
- 10 April 2009
- journal article
- case report
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 11 (5) , 657-659
Abstract
Nowadays, trans-septal (TS) puncture is a relatively safe and straightforward procedure in experienced hands. However, in the presence of a thick, aneurysmatic or extremely elastic fossa ovalis crossing the septum might be challenging. We here describe the use of a novel guidewire that permits easy and safe ‘over the wire’ TS access during atrial fibrillation ablation.Keywords
This publication has 5 references indexed in Scilit:
- First experience with real-time three-dimensional transoesophageal echocardiography-guided transseptal in patients undergoing atrial fibrillation ablationEP Europace, 2008
- Fossa ovalis radiofrequency perforation in a difficult case of conventional transseptal puncture for atrial fibrillation ablationJournal of Interventional Cardiac Electrophysiology, 2008
- Safety of Single Transseptal Puncture for Ablation of Atrial Fibrillation: Retrospective Study from a Large Cohort of PatientsJournal of Cardiovascular Electrophysiology, 2007
- A Conservative Approach to Performing Transseptal Punctures Without the Use of Intracardiac Echocardiography: Stepwise Approach with Real-Time Video ClipsJournal of Cardiovascular Electrophysiology, 2007
- Spontaneous Initiation of Atrial Fibrillation by Ectopic Beats Originating in the Pulmonary VeinsNew England Journal of Medicine, 1998