A new one-step computational procedure is presented for estimating the parameters of the nonlinear three-element windkessel model of the arterial system incorporating a pressure-dependent compliance. The data required are pulsatile aortic pressure and flow. The basic assumptions are a steadystate periodic regime and a purely elastic compliant element. By stating two conditions, zero mean flow and zero mean power in the compliant element, peripheral and characteristic resistances are determined through simple closed form formulas as functions of mean values of the square of aortic pressure, the square of aortic flow, and the product of aortic pressure with aortic flow. The pressure across as well as the flow through the compliant element can be then obtained so allowing the calculation of volume variation and compliance as functions of pressure. The feasibility of this method is studied by applying it to both simulated and experimental data relative to different circulatory conditions and comparing the results with those obtained by an iterative parameter optimization algorithm and with the actual values when available. The conclusion is that the proposed method appears to be effective in identifying the three-element windkessel even in the case of nonlinear compliance.Keywords
This publication has 14 references indexed in Scilit:
- A nonlinear model of the arterial system incorporating a pressure-dependent complianceIEEE Transactions on Biomedical Engineering, 1990
- Comparison of time domain algorithms for estimating aortic characteristic impedance in humansIEEE Transactions on Biomedical Engineering, 1988
- Total systemic arterial compliance and aortic characteristic impedance in the dog as a function of pressure: A model based studyComputers and Biomedical Research, 1987
- Reduced Models of Arterial SystemsIEEE Transactions on Biomedical Engineering, 1985
- Computer identification of models for the arterial tree input impedance: Comparison between two new simple models and first experimental resultsMedical & Biological Engineering & Computing, 1982
- Characteristic impedance of the proximal aorta determined in the time and frequency domain: a comparisonMedical & Biological Engineering & Computing, 1981
- Quantitative evaluation of the systemic arterial bed by parameter estimation of a simple modelMedical & Biological Engineering & Computing, 1980
- Influence of central and peripheral changes on the hydraulic input impedance of the systemic arterial treeMedical & Biological Engineering & Computing, 1973
- A nonlinear analysis of pulsatile flow in arteriesJournal of Fluid Mechanics, 1972
- The static elastic properties of the arterial wallThe Journal of Physiology, 1961