Femoral Nerve Palsy After Pelvic Fracture Treated With INFIX

Authors:
  • UKUtku Kandmir
    Utku Kandmir
  • BSBrian Solberg
    Brian Solberg
  • ASAlex Stroh
    Alex Stroh
  • GOGreg Osgood
    Greg Osgood
  • SSStephen A. Sems
    Stephen A. Sems
  • CCCory A. Collinge
    Cory A. Collinge

Abstract
The treatment of some pelvic injuries has evolved recently to include the use of a subcutaneous anterior pelvic fixator (INFIX). We present 8 cases of femoral nerve palsy in 6 patients after application of an INFIX to highlight this potentially devastating complication to pelvic surgeons using this technique and discuss how it might be avoided in the future. Retrospective chart review. Case series. Five level 1 and 2 trauma centers, tertiary referral hospitals. Six patients with anterior pelvic ring injury treated with an INFIX who experienced 8 femoral nerve palsies (2 bilateral). Removal of internal fixator, treatment for femoral nerve palsy. Clinical and electromyographic evaluation of patients. All 6 patients with a total of 8 femoral nerve palsies had their INFIX removed. Variable resolution of the nerve injuries was observed. Application of an INFIX for the treatment of pelvic ring injury carries a potentially devastating risk to the femoral nerve(s). Despite early implant removal after detection of nerve injury, some patients had residual quadriceps weakness, disturbance of the thigh's skin sensation, and/or gait disturbance attributable to femoral nerve palsy at the time of early final follow-up. Therapeutic level IV. See Instructions for Authors for a complete description of levels of evidence.

This publication has 27 references indexed in Scilit: