The usefulness of near-infrared spectroscopy in the anesthetic management of endovascular aortic aneurysm repair
- 26 June 2012
- journal article
- Published by Springer Nature in Journal of Anesthesia
- Vol. 26 (6) , 932-935
Abstract
Near-infrared spectroscopy (NIRS) may be a useful method for monitoring the regional oxygen saturation (rSO2) of the lower extremity during endovascular aortic repair. Eighteen patients with thoracic descending and/or abdominal aortic aneurysm were enrolled in this study. NIRS probes were placed bilaterally on the calves. Muscular rSO2 (mrSO2) was monitored every 30 s throughout the operation. In the leg in which the femoral artery was clamped, mrSO2 values were selected at 3 or 4 points–just before clamping (control value), 30 min after clamping, 10 min after the first declamping, and 10 min after the second declamping following repair of the femoral artery, if necessary. In all patients, mrSO2 decreased significantly during clamping, from 64 ± 11 % (mean ± SD) of the control value to 32 ± 15 %. After declamping, mrSO2 recovered to 69 ± 14 % of the control value in 16 patients. In the 2 other patients, however, mrSO2 did not recover after the first declamping, because of femoral artery dissection. After additional repair, mrSO2 recovered quickly to the control value. These data suggested NIRS may objectively and quantitatively reflect oxygenation of the lower extremities, and may indicate an ischemic event that needs additional repair during endovascular aortic repair.Keywords
This publication has 23 references indexed in Scilit:
- Primary Stenting Immediatly after Surgery in Occluded Anastomoses of Aortoaortic Tube Graft: A Case ReportCardiology Research and Practice, 2010
- Distal Leg Protection for Peripheral Cannulation in Minimally Invasive and Totally Endoscopic Cardiac SurgeryThe Heart Surgery Forum, 2009
- Detection of Lower Torso Ischemia by Near-Infrared Spectroscopy During Cardiopulmonary Bypass in a 6.8-Kg Infant With Complex Aortic AnatomyThe Annals of Thoracic Surgery, 2006
- Near infrared spectroscopy monitoring during pediatric aortic coarctation repairPediatric Anesthesia, 2006
- Neurological Monitoring for Congenital Heart SurgeryAnesthesia & Analgesia, 2004
- Limb Ischemia and Reperfusion During Abdominal Aortic Aneurysm SurgerySurgery Today, 2004
- Monitoring of skeletal muscle oxygenation using near-infrared spectroscopy during abdominal aortic surgeryJournal of Anesthesia, 2002
- Detection of soft-tissue hyperemia: value of power Doppler sonography.American Journal of Roentgenology, 1994
- Clinically unsuspected complications of arterial surgery shown by post-operative digital substraction angiographyBritish Journal of Radiology, 1989
- Early and Long-term Results after Surgical Treatment of Abdominal Aortic Aneurysm*The Thoracic and Cardiovascular Surgeon, 1981