Enhancing rotational placement of reconstruction prostheses of the distal femur after sarcoma resection
Open Access
- 16 May 2020
- journal article
- research article
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 81 (1) , 47-57
Abstract
Currently there are no accepted international guidelines for the correct placement of reconstruction prostheses in the axial plane of the femur after en bloc resection. The most accepted method is based on the linea aspera as an intraoperative landmark, indicating posterior. This study was conducted to address the reliability of the linea aspera as a landmark for rotational alignment. 50 CT angiographies of the right limb were used for this purpose. These 2D images were reconstructed into 3D models using proprietary software (materialize NV, Leuven, Belgium). The posterior condylar line was used as a reference axis. The orientation of the linea aspera was described as the angle between the perpendicular line to the PCL, through the center of the diaphysis, and the lateral (α) and medial labium (β). The linear mixed model shows that the α- and β-angles are significantly associated with the distance from the joint line (p<0.001) and vary significantly between subjects (p<0.001). The α-angle has the lowest variance and approximates more closely true posterior, while the median β-angle never overlaps true posterior. When a surgeon would blindly rely on the linea aspera as a posterior landmark roughly 78% of the femoral implants would exceed the accepted ±3° deviation around the surgical transepicondylar axis (sTEA) as defined in total knee replacement. The linea aspera is not a reliable landmark for axial rotation of femoral implants. The position is highly dependent on the osteotomy height and in addition differs between individual patients. Preoperative assessment of the linea aspera is advocated in order to reduce the risk of malrotation. As the height of the osteotomy cannot always be determined correctly preoperatively, a table was designed as a guideline for how much a deviation from the planned resection height will affect the rotation of the implant.Keywords
This publication has 29 references indexed in Scilit:
- Aseptic Failure: How Does the Compress® Implant Compare to Cemented Stems?Clinical Orthopaedics and Related Research, 2012
- Serum metal ion levels after rotating-hinge knee arthroplasty: comparison between a standard device and a megaprosthesisInternational Orthopaedics, 2011
- The linea asperapilaster complex as a possible cause of confusion with the ‘flame sign’: a case reportActa Orthopaedica et Traumatologica Turcica, 2010
- Cemented Distal Femoral Endoprostheses for Musculoskeletal Tumor: Improved Survival of Modular versus Custom ImplantsClinical Orthopaedics and Related Research, 2009
- How precise can bony landmarks be determined on a CT scan of the knee?The Knee, 2009
- A common reference frame for describing rotation of the distal femurThe Journal of Bone and Joint Surgery. British volume, 2009
- Compressive osseointegration promotes viable bone at the endoprosthetic interface: retrieval study of Compress® implantsInternational Orthopaedics, 2007
- Endoprosthetic replacement of the distal femur for bone tumoursThe Journal of Bone and Joint Surgery. British volume, 2007
- When to use agreement versus reliability measuresJournal of Clinical Epidemiology, 2006
- Early distal femoral endoprosthetic survival: cemented stems versus the Compress® implantInternational Orthopaedics, 2006