10 Years of Emergency Endovascular Aneurysm Repair for Ruptured Abdominal Aortoiliac Aneurysms: Lessons Learned
Authors:
- Dieter MayerDMDieter Mayer
- Thomas PfammatterTPThomas Pfammatter
- Zoran RancicZRZoran Rancic
- Lukas HechelhammerLHLukas Hechelhammer
- Markus WilhelmMWMarkus Wilhelm
- Frank J. VeithFVFrank J. Veith
- Mario LachatMLMario Lachat
- 1 March 2009
- journal article
- Published by Wolters Kluwer Health in Annals of Surgery
- Vol. 249 (3) , 510-515
Abstract
To evaluate a single center's 10-year experience with emergency endovascular aneurysm repair (eEVAR) in 102 patients with ruptured abdominal aortoiliac aneurysms (RAAA). Data from 102 patients (mean age, 73 +/- 9 years) with RAAA treated by eEVAR from January 1998 to April 2008 were retrospectively reviewed. From January 2000, all patients were treated according to an intention-to-treat protocol. The only exclusion criterion was unsuitable anatomy. 31/102 patients had moderate shock and 14/102 patients had severe shock with a systolic blood pressure 20 mm Hg. The 30-day mortality for eEVAR was 13% (13/102). Technical success (defined as successful deployment of the endograft, absence of extravasation in the postprocedural contrast enhanced CT scan and hemodynamic stabilization) was 99% (101/102). Nineteen unstable patients (19%) required transfemoral supraceliac aortic balloon occlusion. ACS was detected and treated by OAT in 20 patients (20%). 16 type I, 26 type II and 1 type III endoleaks were detected on postoperative CT examination. Two patients had a combined type I and II endoleak. 11 patients were retreated for immediate correction of 10 type I and 2 type II endoleaks. 6 type I and 1 type III low-flow endoleaks were observed and resolved spontaneously within 30 days. Major 30-day morbidity was 35%. In this 102 patient contemporary series of eEVAR for RAAA, endografting proved to be safe with a 30-day mortality of 13%. Key components of this favorable outcome result were adequate preoperative diagnostic imaging, hypotensive hemostasis, selective transfemoral supraceliac aortic balloon occlusion, predominantly local anesthesia, detection and treatment of ACS, and attention to logistics. Widespread adoption of these treatment components is recommended.Keywords
This publication has 36 references indexed in Scilit:
- Improved Hybrid Technique for Vascular Access and ClosureJournal of Endovascular Therapy, 2008
- A meta-analysis of 21 178 patients undergoing open or endovascular repair of abdominal aortic aneurysmBritish Journal of Surgery, 2008
- Endovascular repair of ruptured abdominal aortic aneurysms: A systematic review and meta-analysisJournal of Vascular Surgery, 2008
- In Vitro Comparison of Intra-Abdominal Hypertension Development After Different Temporary Abdominal Closure TechniquesJournal of Surgical Research, 2007
- Early and Midterm Results After Open and Endovascular Repair of Ruptured Abdominal Aortic Aneurysms in a Comparative AnalysisJournal of Endovascular Therapy, 2007
- Endovascular repair versus open surgery in patients with ruptured abdominal aortic aneurysms: Clinical outcomes with 1-year follow-upJournal of Vascular Surgery, 2006
- Balloon Occlusion of the Aorta During Endovascular Repair of Ruptured Abdominal Aortic AneurysmJournal of Endovascular Therapy, 2005
- Endovascular Repair with Bifurcated Stent-Grafts under Local Anaesthesia to Improve Outcome of Ruptured Aortoiliac AneurysmsEuropean Journal of Vascular and Endovascular Surgery, 2002
- A meta-analysis of 50 years of ruptured abdominal aortic aneurysm repairBritish Journal of Surgery, 2002
- Emergency endovascular repair of leaking aortic aneurysmThe Lancet, 1994