Engineered cartilage is a promising option for auricular reconstruction. We have previously demonstrated that a titanium wire framework within a composite collagen ear-shaped scaffold helped to maintain the gross dimensions of the engineered ear after implantation, resisting the deformation forces encountered during neocartilage maturation and wound healing. The ear geometry was redesigned to achieve a more accurate aesthetic result when implanted subcutaneously in a nude rat model. A non-invasive method was developed to assess size and shape changes of the engineered ear in three dimensions. Computer models of the titanium framework were obtained from CT scans before and after implantation . Several parameters were measured including the overall length, width and depth, the minimum intrahelical distance and overall curvature values for each beam section within the framework. Local curvature values were measured to gain understanding of the bending forces experienced by the framework structure in situ . Length and width changed by less than 2%, whereas the depth decreased by approximately 8% and the minimum intrahelical distance changed by approximately 12%. Overall curvature changes identified regions most susceptible to deformation. Eighty-nine per cent of local curvature measurements experienced a bending moment less than 50 µN-m owing to deformation forces during implantation. These quantitative shape analysis results have identified opportunities to improve shape fidelity of engineered ear constructs.Keywords
This publication has 25 references indexed in Scilit:
- Engineering Ear Constructs with a Composite Scaffold to Maintain DimensionsTissue Engineering Part A, 2011
- Biodegradable Elastomers for Tissue Engineering and Cell–Biomaterial InteractionsMacromolecular Bioscience, 2011
- Computational Tools for Quantitative Breast Morphometry Based on 3D ScansAnnals of Biomedical Engineering, 2010
- In vitro engineering of human ear-shaped cartilage assisted with CAD/CAM technologyBiomaterials, 2010
- Tissue engineering a model for the human ear: Assessment of size, shape, morphology, and gene expression following seeding of different chondrocytesWound Repair and Regeneration, 2009
- Water‐Soluble Sacrificial Layers for Surface MicromachiningSmall, 2005
- Tissue Engineering of an Auricular Cartilage Model Utilizing Cultured Chondrocyte–Poly(L-lactide-ε-caprolactone) ScaffoldsTissue Engineering, 2004
- Analysis of bending behavior of native and engineered auricular and costal cartilageJournal of Biomedical Materials Research Part A, 2004
- Measuring tortuosity of the intracerebral vasculature from MRA imagesIEEE Transactions on Medical Imaging, 2003
- Auricular Reconstruction: Indications for Autogenous and Prosthetic TechniquesPlastic and Reconstructive Surgery, 2001