A Retrospective Comparison of Hemodynamic and Clinical Outcomes between Two Differently Designed Aortic Bioprostheses for Small Aortic Annuli
Open Access
- 4 March 2021
- journal article
- research article
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (5) , 1063
Abstract
The Trifecta valve has externally mounted leaflets; it differs from classic internally mounted valves (e.g., Carpentier-Edwards [C-E]). We evaluated post-implantation hemodynamics and clinical outcomes of these bioprostheses in small aortic annuli. From January 2015 to April 2019, 490 patients who underwent aortic valve replacement (AVR) were reviewed retrospectively. Altogether, 183 patients received 19 or 21 mm diameter C-E (n = 121) or Trifecta (n = 62) prostheses. To minimize confounding variables, we performed propensity-score matching analysis. The mean transvalvular pressure gradient (TVPG) was significantly lower in the Trifecta than in the C-E group at discharge (12.9 ± 4.8 vs. 15.0 ± 5.3 mmHg, p = 0.044). TVPG change over time was not significantly different between groups (p = 0.357). Left ventricular mass index decreased postoperatively (reduction: C-E, 28.1%; Trifecta, 30.1%, p = 0.879). No late mortality, severe patient–prosthesis mismatch, moderate-to-severe paravalvular leakage, structural valve degeneration, or valve thromboses were observed. Freedom from valve-related events at 3 years were similar for C-E (97.9% ± 2.1%) and Trifecta (97.7% ± 2.2%) patients (log-rank p = 0.993). Bioprosthesis design for small annuli significantly affected TVPG immediately after AVR. However, hemodynamics over time and clinical outcomes did not differ between the two designs.Keywords
This publication has 34 references indexed in Scilit:
- Comparison of early haemodynamics of 19-mm aortic valve bioprostheses in patients with a small aortic annulusInteractive CardioVascular and Thoracic Surgery, 2015
- Recommendations for Cardiac Chamber Quantification by Echocardiography in Adults: An Update from the American Society of Echocardiography and the European Association of Cardiovascular ImagingEuropean Heart Journal - Cardiovascular Imaging, 2015
- Comparison of early hemodynamic performance of 3 aortic valve bioprosthesesThe Journal of Thoracic and Cardiovascular Surgery, 2014
- Incidence and Sequelae of Prosthesis-Patient Mismatch in Transcatheter Versus Surgical Valve Replacement in High-Risk Patients With Severe Aortic StenosisJACC, 2014
- The new St Jude Trifecta versus Carpentier-Edwards Perimount Magna and Magna Ease aortic bioprosthesis: Is there a hemodynamic superiority?The Journal of Thoracic and Cardiovascular Surgery, 2014
- The St Jude Medical Trifecta aortic pericardial valve: Results from a global, multicenter, prospective clinical studyThe Journal of Thoracic and Cardiovascular Surgery, 2014
- Prosthesis–Patient Mismatch is Not Clinically Relevant in Aortic Valve Replacement Using the Carpentier-Edwards Perimount ValveThe Annals of Thoracic Surgery, 2006
- Impact of Valve Prosthesis-Patient Mismatch on Short-Term Mortality After Aortic Valve ReplacementCirculation, 2003
- Choice of prosthetic heart valve for adult patientsJACC, 2003
- Echocardiographic assessment of left ventricular hypertrophy: Comparison to necropsy findingsThe American Journal of Cardiology, 1986