Clinical use of the modified shuttle test in children with cystic fibrosis: Is one test sufficient?
- 2 March 2021
- journal article
- research article
- Published by Wiley in Pediatric Pulmonology
- Vol. 56 (6) , 1550-1557
Abstract
Objective: To evaluate the reproducibility of the modified shuttle test (MST) and to determine whether the test needs to be performed more than once to assess the exercise capacity of children and adolescents with cystic fibrosis (CF).Methods: This was a longitudinal study including patients diagnosed with CF aged more than 6 years. The participants were followed for a period of 9 months and were evaluated at three different time points (visits 1, 2, and 3). Spirometric, anthropometric, clinical, and genetic data were collected, and two MSTs were performed at each visit.Results: Forty‐eight clinically stable volunteers with a mean age of 10.1 ± 2.7 years were initially included. The reproducibility of the test was evaluated using the distance achieved (DA) as the main variable. There were no significant differences in the DA (visit 1, p = .23; visit 2, p = .24; visit 3, p = .85), baseline heart rate (HR) (visit 1, p = .35; visit 2, p = .20; visit 3, p = .98), and peak HR (visit 1, p = .16; visit 2, p = .94; visit 3, p = .23) between the tests performed at each visit. The test‐retest reliability demonstrated a high intraclass correlation coefficient at all visits (visit 1, 2, and 3: 0.83, 0.90, and 0.80, respectively) and the variation in HR was the main factor associated with the DA in the MST over time.Conclusion: The MST was found to be a reproducible and reliable test. The data presented here support the use of a single MST to evaluate and monitor exercise capacity of patients with CF during clinic visits.Keywords
This publication has 33 references indexed in Scilit:
- Physical activity levels of patients with cystic fibrosis hospitalised with an acute respiratory exacerbationRespiratory Medicine, 2013
- The evolution of exercise capacity and its limiting factors in Cystic FibrosisPaediatric Respiratory Reviews, 2012
- Multi-ethnic reference values for spirometry for the 3–95-yr age range: the global lung function 2012 equationsEuropean Respiratory Journal, 2012
- Comparing peak and submaximal cardiorespiratory responses during field walking tests with incremental cycle ergometry in COPDRespirology, 2012
- The role of exercise in maintaining health in cystic fibrosisCurrent Opinion in Pulmonary Medicine, 2011
- Cardiorespiratory measurements during field tests in CF: Use of an ambulatory monitoring systemPediatric Pulmonology, 2010
- Análise comparativa e reprodutibilidade do teste de caminhada com carga progressiva (modificado) em crianças normais e em portadoras de fibrose císticaJornal Brasileiro de Pneumologia, 2007
- Avaliação da capacidade de exercício em portadores de doença pulmonar obstrutiva crônica: comparação do teste de caminhada com carga progressiva com o teste de caminhada com acompanhamentoJornal Brasileiro de Pneumologia, 2006
- Standardisation of spirometryEuropean Respiratory Journal, 2005
- Validation of shuttle tests in children with cystic fibrosisPediatric Pulmonology, 2003