A mouse model to evaluate the interface between skin and a percutaneous device
Authors:
- 13 June 2007
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 83A (4) , 915-922
Abstract
Percutaneous medical devices are integral in the management and treatment of disease. The space created between the skin and the device becomes a haven for bacterial invasion and biofilm formation and results in infection. We hypothesize that sealing this space via integration of the skin into the device will create a barrier against bacterial invasion. The purpose of this study was to develop an animal model in which the interaction between skin and biomaterials can be evaluated. Porous poly(2‐hydroxyethyl methacrylate) [poly(HEMA)] rods were implanted for 7 days in the dorsal skin of C57 BL/6 mice. The porous poly(HEMA) rods were surface‐modified with carbonyldiimidazole (CDI) or CDI plus laminin 5; unmodified rods served as control. Implant sites were sealed with 2‐octyl cyanoacrylate; corn pads and adhesive dressings were tested for stabilization of implants. All rods remained intact for the duration of the study. There was histological evidence of both epidermal and dermal integration into all poly(HEMA) rods regardless of treatment. This in vivo model permits examination of the implant/skin interface and will be useful for future studies designed to facilitate skin cell attachment where percutaneous devices penetrate the skin. © 2007 Wiley Periodicals, Inc. J Biomed Mater Res, 2007Keywords
This publication has 32 references indexed in Scilit:
- A model for studying epithelial attachment and morphology at the interface between skin and percutaneous devicesJournal of Biomedical Materials Research Part A, 2005
- Cardiac Device Implant Wound Closure with 2-Octyl CyanoacrylateJournal of Interventional Cardiology, 2005
- Candidacy for the Bone-Anchored Hearing AidAudiology and Neurotology, 2004
- Evaluation of a New High‐viscosity Octylcyanoacrylate Tissue Adhesive for Laceration Repair: A Randomized, Clinical TrialAcademic Emergency Medicine, 2003
- Characterization and analysis of osteopontin‐immobilized poly(2‐hydroxyethyl methacrylate) surfacesJournal of Biomedical Materials Research Part A, 2003
- In-Vitro Analysis for Microbial Barrier Properties of 2-Octyl Cyanoacrylate-Derived Wound Treatment FilmsJournal of Cutaneous Medicine and Surgery, 2002
- In Vitro Assessment of Microbial Barrier Properties of Dermabond ® Topical Skin AdhesiveSurgical Infections, 2002
- Development of a new percutaneous access device for implantation in soft tissuesJournal of Biomedical Materials Research, 1991
- A light and electron microscopic study of the effects of surface topography on the behavior of cells attached to titanium‐coated percutaneous implantsJournal of Biomedical Materials Research, 1991
- Transcutaneous implants: Reactions of the skin‐implant interfaceJournal of Biomedical Materials Research, 1974