Characterization of Benign and Malignant Solid Breast Masses: Comparison of Conventional US and Tissue Harmonic Imaging
Authors:
- Woo Kyung MoonWMWoo Kyung Moon
- Nariya ChoNCNariya Cho
- Sun Mi KimSKSun Mi Kim
- Seong Ho ParkSPSeong Ho Park
- Boo-Kyung HanBHBoo-Kyung Han
- Yeon Hyeon ChoeYCYeon Hyeon Choe
- Jeong Mi ParkJPJeong Mi Park
- Jung-Gi ImJIJung-Gi Im
- 1 January 2007
- journal article
- research article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 242 (1) , 63-69
Abstract
To prospectively compare the diagnostic performance of radiologists by using conventional ultrasonography (US) and tissue harmonic imaging for the differentiation of benign from malignant solid breast masses, with histologic results used as the reference standard. The study was approved by the institutional review board, and informed consent was obtained from all patients. Images were obtained with conventional US and tissue harmonic imaging in 88 patients (age range, 25-67 years; mean age, 45 years) with 91 solid breast masses (30 cancers and 61 benign lesions) before excisional or needle biopsy. Three experienced radiologists, who did not perform the examinations, independently analyzed the US findings and provided a level of suspicion to indicate the probability of malignancy. Results were evaluated by using kappa statistics and receiver operating characteristic (ROC) analyses. Regarding the descriptions of US findings, echogenicity (kappa=0.205) was the most discordant between conventional US and tissue harmonic imaging, followed by margin (kappa=0.495), lesion boundary (kappa=0.495), calcifications (kappa=0.537), posterior acoustic transmission (kappa=0.546), echotexture (kappa=0.586), shape (kappa=0.591), and orientation (kappa=0.594). The area under the ROC curve (Az) for conventional US and tissue harmonic imaging was 0.84 and 0.79, respectively, for reader 1; 0.88 and 0.85, respectively, for reader 2; and 0.91 and 0.89, respectively, for reader 3. The overall Az value for the three readers was 0.88 for conventional US and 0.84 for tissue harmonic imaging (95% confidence interval: -0.0950, 0.1646; P=.595). The performance of the radiologists with respect to the characterization of solid breast masses as benign or malignant was not significantly improved with tissue harmonic imaging.Keywords
This publication has 16 references indexed in Scilit:
- Suspected Rotator Cuff Lesions: Tissue Harmonic Imaging versus Conventional US of the ShoulderRadiology, 2004
- Tissue Harmonic ImagingJournal of Ultrasound in Medicine, 2003
- Benefits of tissue harmonic imaging in the evaluation of abdominal and pelvic lesionsAbdominal Radiology, 2003
- Multifocal, Multicentric, and Contralateral Breast Cancers: Bilateral Whole-Breast US in the Preoperative Evaluation of PatientsRadiology, 2002
- US of Ductal Carcinoma In SituRadioGraphics, 2002
- Sonographic Evaluation of Breast Nodules: Comparison of Conventional, Real-Time Compound, and Pulse-Inversion Harmonic ImagesKorean Journal of Radiology, 2002
- Tissue harmonic imaging sonography of breast lesionsClinical Imaging, 2001
- Clinical use of ultrasound tissue harmonic imagingUltrasound in Medicine & Biology, 1999
- Tissue harmonic imaging sonography: evaluation of image quality compared with conventional sonography.American Journal of Roentgenology, 1998
- Solid breast nodules: use of sonography to distinguish between benign and malignant lesions.Radiology, 1995