Abstract
Traditional methods for calculations of active loads on retaining structures provide dependable forces, but these methods do not indicate reliably the location of the resultant load on the walls. The Coulomb method does not address the load distribution because it utilizes equilibrium of forces, whereas the Rankine stress distribution provides linear increase of the load with depth. Past experimental studies indicate intricate distributions dependent on the mode of displacement of the wall before reaching the limit state. The discrete element method was used to simulate soil-retaining structure interaction, and force chains characteristic of arching were identified. Arching appears to be the primary cause affecting the load distribution. A differential slice technique was used to mimic the load distributions seen in physical experiments. The outcome indicates that rotation modes of wall movement are associated with uneven mobilization of strength on the surface separating the moving backfill from ...