The Effect of Slice Thickness on the Assessment of Bone Defect Volumes by the Cavalieri Principle Using Cone Beam Computed Tomography
Open Access
- 27 April 2012
- journal article
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 26 (1) , 115-118
Abstract
The purpose of this study was to investigate the possible effects of section thickness on volume estimations obtained by cone beam computed tomography. Intraosseal cavities representing bone defects on vestibular sides of the two dry sheep mandibles were scanned by a cone beam computed tomography system. Consecutive sections at 0.2, 0.6, 1, 1.4, and 2.2 mm thickness were used to estimate the volumes of the cavities using the Cavalieri principle of stereological methods. Estimated volumes are then compared with the volumes obtained by the Archimedean principle. In 0.2-, 0.6-, and 1-mm-thick slices, the volumes estimated by the Cavalieri principle did not differ from the volumes by the Archimedean principle (p > 0.05). The 0.2 mm slice-thickness group had the highest asymptotic significance value (p = 0.6). Although the thinnest slice appears to provide the most accurate values, slice thickness up to 1 mm can be chosen for volume calculations on CBCT images.Keywords
This publication has 20 references indexed in Scilit:
- Comparative dosimetry of dental cone beam computed tomography, panoramic radiography, and multislice computed tomographyOral Radiology, 2011
- The estimation of the volume of sheep mandibular defects using cone-beam computed tomography images and a stereological methodDentomaxillofacial Radiology, 2011
- Comparison between effective radiation dose of CBCT and MSCT scanners for dentomaxillofacial applicationsEuropean Journal of Radiology, 2009
- Comparison of radiation dose for implant imaging using conventional spiral tomography, computed tomography, and cone-beam computed tomographyOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 2009
- Bone healing after dental extractions in irradiated patients: a pilot study on a novel technique for volume assessment of healing tooth socketsClinical Oral Investigations, 2008
- Volumetric analysis of extraction sockets using cone beam computed tomography: a pilot study on ex vivo jaw boneJournal of Clinical Periodontology, 2007
- Comparison of Three Methods for the Estimation of Total Intracranial VolumeAnnals of Plastic Surgery, 2007
- Estimation of the amniotic fluid volume using the Cavalieri method on ultrasound imagesInternational Journal of Gynecology & Obstetrics, 2003
- Comparison of two volumetric techniques for estimating liver volume using magnetic resonance imagingJournal of Magnetic Resonance Imaging, 2002
- The benefit of stereology for quantitative radiology.British Journal of Radiology, 2000