SOIL TEMPERATURE AND WATER EVAPORATION OF SMALL STEEL AND PLASTIC LYSIMETERS REPLACED DAILY
- 1 November 2000
- journal article
- research article
- Published by Wolters Kluwer Health in Soil Science
- Vol. 165 (11) , 890-895
Abstract
Soil water evaporation (E) measured by small, weighable lysimeters is affected by their size, construction materials, and replacement frequency. Steel and plastic are commonly used materials, but they have different thermal characteristics. Our objective was to investigate how wall material affects E and soil temperature of small lysimeters filled daily with undisturbed soil. Research was conducted during 5 days in August 1995 at Bushland, Texas, where the soil is a Pullman silty clay loam (fine, mixed, thermic Torrertic Paleustoll, 30% clay, 53% silt). Plastic and steel lysimeters 76 mm long, with inside diameters of 82 and 86 mm, respectively, were filled each morning by pressing them into undisturbed soil, and E was determined by mass change. Soil temperatures inside additional steel and plastic lysimeters were measured by thermocouples. No significant differences in E due to wall material were measured. For lysimeters of both wall materials, daily E ranged from 2 to 5 mm, daytime and nighttime E averaged 2.7 mm and 0.5 mm, respectively, and total cumulative E was 15.5 mm. Evaporation from small lysimeters was within 5% of E from a nearby large, precision, weighing lysimeter. Steel lysimeters were warmer at night near the surface, with significant differences from 0.5 to 0.9 °C, and warmer during the day at the bottom, with significant differences from 0.5 to 2.8 °C. Plastic lysimeters had greater vertical soil temperature differences than steel lysimeters. Significant differences inside plastic lysimeters ranged from about 2.0 to 3.5 °C greater than those of steel lysimeters during the daytime, and 0.5 to 1.0 °C greater during the nighttime. Measured temperature differences were consistent with greater thermal conductivity and enhanced heat transfer in steel sidewalls compared with plastic. Wall material affected temperature distribution, but not evaporation, of small lysimeters that were replaced daily.Keywords
This publication has 7 references indexed in Scilit:
- Wall Material and Capping Effects on Microlysimeter Temperatures and EvaporationSoil Science Society of America Journal, 1995
- Use of microlysimeters to measure evaporation from sandy soilsAgricultural and Forest Meteorology, 1993
- Measurements of soil, plant and total evaporation from millet in NigerAgricultural and Forest Meteorology, 1993
- Determination of soil water evaporation and transpiration from energy balance and stem flow measurementsAgricultural and Forest Meteorology, 1990
- EVAPORATION MEASUREMENTS AND PREDICTIONS FROM SOILS UNDER CROP CANOPIESTransactions of the ASAE, 1990
- Design and Construction of Large Weighing Monolithic LysimetersTransactions of the ASAE, 1988
- A “Micro‐Lysimeter” Method for Determining Evaporation from Bare Soil: Description and Laboratory EvaluationSoil Science Society of America Journal, 1982