Examination of the Carbon Monoxide Diffusing Capacity (D l CO) in Relation to Its K co and V a Components
- 15 July 2012
- journal article
- review article
- Published by Oxford University Press (OUP) in American Journal of Respiratory and Critical Care Medicine
- Vol. 186 (2) , 132-139
Abstract
The single-breath carbon monoxide diffusing capacity (DlCO) is the product of two measurements during breath holding at full inflation: (1) the rate constant for carbon monoxide uptake from alveolar gas (kco [minute−1]) and (2) the “accessible” alveolar volume (Va). kco expressed per mm Hg alveolar dry gas pressure (Pb*) as kco/Pb*, and then multiplied by Va, equals DlCO; thus, DlCO divided by Va (DlCO/Va, also called Kco) is only kco/Pb* in different units, remaining, essentially, a rate constant. The notion that DlCO/Va “corrects” DlCO for reduced Va is physiologically incorrect, because DlCO/Va is not constant as Va changes; thus, the term Kco reflects the physiology more appropriately. Crucially, the same DlCO may occur with various combinations of Kco and Va, each suggesting different pathologies. Decreased Kco occurs in alveolar–capillary damage, microvascular pathology, or anemia. Increased Kco occurs with (1) failure to expand normal lungs to predicted full inflation (extrapulmonary restriction); or (2) increased capillary volume and flow, either globally (left-to-right intracardiac shunting) or from flow and volume diversion from lost or damaged units to surviving normal units (e.g., pneumonectomy). Decreased Va occurs in (1) reduced alveolar expansion, (2) alveolar damage or loss, or (3) maldistribution of inspired gases with airflow obstruction. Kco will be greater than 120% predicted in case 1, 100–120% in case 2, and 40–120% in case 3, depending on pathology. Kco and Va values should be available to clinicians, as fundamental to understanding the clinical implications of DlCO. The diffusing capacity for nitric oxide (DlNO), and the DlNO/DlCO ratio, provide additional insights.Keywords
This publication has 56 references indexed in Scilit:
- Calculating alveolar capillary conductance and pulmonary capillary blood volume: comparing the multiple- and single-inspired oxygen tension methodsJournal of Applied Physiology, 2010
- Significant blood resistance to nitric oxide transfer in the lungJournal of Applied Physiology, 2010
- Hepatopulmonary Syndrome — A Liver-Induced Lung Vascular DisorderNew England Journal of Medicine, 2008
- Deciphering the nitric oxide to carbon monoxide lung transfer ratio: physiological implicationsThe Journal of Physiology, 2007
- Can a membrane oxygenator be a model for lung NO and CO transfer?Journal of Applied Physiology, 2006
- An open-circuit method for determining lung diffusing capacity during exercise: comparison to rebreatheJournal of Applied Physiology, 2005
- Diffusion capacity and haemodynamics in primary and chronic thromboembolic pulmonary hypertensionEuropean Respiratory Journal, 2000
- A CHRONIC PULMONARY SYNDROME ASSOCIATED WITH GRAFT-VERSUS-HOST DISEASE AFTER ALLOGENEIC MARROW TRANSPLANTATIONTransplantation, 1992
- Determination of lung capillary blood volume and membrane diffusing capacity in man by the measurements of NO and CO transferRespiration Physiology, 1987
- The influence of lung volume on gas transfer in scoliosisRespiratory Medicine, 1982