Temperature dependence of the Fricke dosimeter and spur expansion time in the low-LET high-temperature radiolysis of water up to 350 °C: a Monte-Carlo simulation study
- 9 May 2011
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 13 (22) , 10690-10698
Abstract
Monte-Carlo simulations of the radiolysis of the ferrous sulfate (Fricke) dosimeter with low-linear energy transfer (LET) radiation (such as 60Co γ-rays or fast electrons) have been performed as a function of temperature from 25 to 350 °C. The predicted yields of Fe2+ oxidation are found to increase with increasing temperature up to ∼100–150 °C, and then tend to remain essentially constant at higher temperatures, in very good agreement with experiment. By using a simple method based on the direct application of the stoichiometric relationship that exists between the ferric ion yields so obtained G(Fe3+) and the sum {3 [g(e− aq + H˙) + g(HO2˙)] + g(˙OH) + 2 g(H2O2)}, where g(e− aq + H˙), g(HO2˙), g(˙OH), and g(H2O2) are the primary radical and molecular yields of the radiolysis of deaerated 0.4 M H2SO4 aqueous solutions, the lifetime (τs) of the spur and its temperature dependence have been determined. In the spirit of the spur model, τs is an important indicator for overlapping spurs, giving the time required for the changeover from nonhomogeneous spur kinetics to homogeneous kinetics in the bulk solution. The calculations show that τs decreases by about an order of magnitude over the 25–350 °C temperature range, going from ∼4.2 × 10−7 s at 25 °C to ∼5.7 × 10−8 s at 350 °C. This decrease in τs with increasing temperature mainly originates from the quicker diffusion of the individual species involved. Moreover, the observed dependence of G(Fe3+) on temperature largely reflects the influence of temperature upon the primary free-radical product yields of the radiolysis, especially the yield of H˙ atoms. Above ∼200–250 °C, the more and more pronounced intervention of the reaction of H˙ atoms with water also contributes to the variation of G(Fe3+), which may decrease or increase slightly, depending on the choice made for the rate constant of this reaction. All calculations reported herein use the radiolysis database of Elliot (Atomic Energy of Canada Limited) and Bartels (University of Notre Dame) that contains all the best currently available information on the rate constants, reaction mechanisms, and g-values in the range 20 to 350 °C.Keywords
This publication has 43 references indexed in Scilit:
- Monte Carlo simulation study of the effects of acidity and LET on the primary free-radical and molecular yields of water radiolysis — Application to the Fricke dosimeterCanadian Journal of Chemistry, 2007
- Effect of Multiple Ionization on the Yield of H2O2Produced in the Radiolysis of Aqueous 0.4MH2SO4Solutions by High-LET12C6+and20Ne9+IonsRadiation Research, 2005
- On the temperature dependence of the primary yield and the product Gεmax of hydrated electrons in the low-LET radiolysis of liquid waterCanadian Journal of Chemistry, 2002
- Radiolysis of Liquid Water at Temperatures up to 300 °C: A Monte Carlo Simulation StudyThe Journal of Physical Chemistry A, 2000
- Temperature Dependence of g Values for Aqueous Solutions Irradiated with 23 MeV 2H+ and 157 MeV 7Li3+ Ion BeamsThe Journal of Physical Chemistry, 1996
- Pulse radiolysis study of concentrated sulfuric acid solutions. Formation mechanism, yield and reactivity of sulfate radicalsJournal of the Chemical Society, Faraday Transactions, 1992
- Rate Constants for Reactions of Inorganic Radicals in Aqueous SolutionJournal of Physical and Chemical Reference Data, 1988
- Aqueous chemical dosimetryThe International Journal of Applied Radiation and Isotopes, 1982
- Pulse radiolysis at high temperatures and high pressuresRadiation Physics and Chemistry (1977), 1981
- Effect of temperature on the .gamma. radiolysis of aqueous solutionsThe Journal of Physical Chemistry, 1972