Toward soft robots you can depend on
Authors:
- 12 September 2008
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics & Automation Magazine
- Vol. 15 (3) , 31-41
Abstract
In this article, we performed an analysis of the dependability of an elementary yet critical robot component, i.e., the joint-level actuation subsystem. We consider robot actuators that implement the VSA paradigm, i.e., ability to change the effective transmission stiffness during motion to achieve high performance while constantly keeping injury risks by accidental impacts with humans below a given threshold. Without attempting a comprehensive review of different existing design approaches to VSA,we focused on the analysis of three different arrangements of agonistic/antagonistic actuation mechanisms for pHRI applications. Several aspects of their performance, safety, and dependability have been considered to get an indicative, though certainly not exhaustive, comparison of these alternatives. According to our results, the simple AA arrangement is more reliable (due to the simplicity of its mechanical implementation) if FM is not used. Proper FM actions can make other designs perform equally well as the simple AA concerning reliability and can perform better for steerability. Simulations of impacts in failed states (where FMis not used by a worst-case assumption) also show that the different designs have comparable safety properties. Although overall results for the bidirectional arrangements are somewhat superior, especially in terms of steerability (if FM is applied), we do not extrapolate any general claim in this regard. Indeed, many factors influence the results of similar studies, and each case should be considered in detail and very carefully. The scope of the study can become quite broad, and many of the theoretical and technical issues presented here (e.g., fault detection, supervisory control, and safety-related systems) will require further separated investigations. One of the purposes of this work was to explore and further promote dependability studies in robotics, as a means of addressing concerns in safety-critical robotic systems for physical interactions with humans. In this sense, a robot for pHRI applications is a unique benchmark for improving the state of art of fault tolerant design as well as in developing tools to master performance, dependability, and safety issues of a robotic structure.Keywords
This publication has 27 references indexed in Scilit:
- Safety for Physical Human–Robot Interaction2008
- Dependability and performability analysis2005
- Design of Lightweight Lead Screw Actuators for Wearable Robotic ApplicationsJournal of Mechanical Design, 2005
- Basic concepts and taxonomy of dependable and secure computingIEEE Transactions on Dependable and Secure Computing, 2004
- Fast and "Soft-Arm" TacticsIEEE Robotics & Automation Magazine, 2004
- Safety Evaluation Method of Design and Control for Human-Care RobotsThe International Journal of Robotics Research, 2003
- Implementation of variable joint stiffness through antagonistic actuation using rolamite springsMechanism and Machine Theory, 1999
- Dependability — Its Attributes, Impairments and Means1995
- A dynamic fault tolerance framework for remote robotsIEEE Transactions on Robotics and Automation, 1995
- Adaptive control of mechanical impedance by coactivation of antagonist musclesIEEE Transactions on Automatic Control, 1984