Time spatial labeling inversion pulse cerebral MR angiography without subtraction by use of dual inversion recovery background suppression
- 1 December 2010
- journal article
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 4 (1) , 78-83
Abstract
Time-spatial labeling inversion pulse (time-SLIP), which is a technique of nonenhanced magnetic resonance angiography (MRA) based on arterial spin labeling (ASL), is used in various situations. Although subtraction between the images obtained with and without ASL is usually employed in cerebral time-SLIP MRA, to reduce the imaging time, dual inversion recovery (IR) has been applied for suppression of the background signals in this study. Appropriate timings for the 1st IR, 2nd IR, and the interval of data acquisition were investigated using computer simulation and a phantom experiment. With a short interval of data acquisition, the visibility of the simulated vessel was inadequate because replacement of the suppressed flow was insufficient. With a long interval of data acquisition, the contrast between the vessel and background was reduced. The reasons for this appeared to be the following: the longitudinal magnetization of the replaced flow is reduced because of the prolonged 2nd inversion time, causing a mismatch of the null point between the calculated and the actual values to become prominent. As a result, 3-4 s seemed to be an appropriate interval for data acquisition. Sufficient angiographic information could be obtained by use of dual IR background suppression in a volunteer study. With this technique, cerebral time-SLIP MRA can be performed in half of the imaging time required with the conventional subtraction technique.Keywords
This publication has 18 references indexed in Scilit:
- Visualization of external carotid artery and its branches: Non-contrast-enhanced MR angiography using balanced steady-state free-precession sequence and a time-spatial labeling inversion pulseJournal of Magnetic Resonance Imaging, 2009
- Improved arterial visibility using short‐tau inversion‐recovery (STIR) fat suppression in non‐contrast‐enhanced time–spatial labeling inversion pulse (Time‐SLIP) renal MR angiography (MRA)Journal of Magnetic Resonance Imaging, 2009
- Time‐resolved three‐dimensional magnetic resonance digital subtraction angiography without contrast material in the brain: Initial investigationJournal of Magnetic Resonance Imaging, 2009
- Non-contrast-enhanced hepatic MR angiography with true steady-state free-precession and time spatial labeling inversion pulse: Optimization of the technique and preliminary resultsEuropean Journal of Radiology, 2009
- High‐resolution intracranial and cervical MRA at 3.0T: Technical considerations and initial experienceMagnetic Resonance in Medicine, 2001
- Magnetic Resonance Angiography of Cerebral Arteriovenous MalformationsNeurologia medico-chirurgica, 1995
- Intracranial MR angiography: comparison of single-volume three-dimensional time-of-flight and multiple overlapping thin slab acquisition techniques.American Journal of Roentgenology, 1994
- Signal targeting with alternating radiofrequency (STAR) sequences: Application to MR angiographyMagnetic Resonance in Medicine, 1994
- Multiple inversion recovery reduces static tissue signal in angiogramsMagnetic Resonance in Medicine, 1991
- MR angiography by selective inversion recoveryMagnetic Resonance in Medicine, 1987