Influence of Continuous Rotation and Optimal Torque Reverse Kinematics on the Cyclic Fatigue Strength of Endodontic NiTi Clockwise Cutting Rotary Instruments
Open Access
- 30 September 2024
- journal article
- research article
- Published by MDPI AG in Dentistry Journal
- Vol. 12 (10) , 317
Abstract
Objectives: The objective of the present study was to evaluate the cyclic fatigue strength of clockwise cutting rotary endodontic instruments when subjected to two different kinematics: continuous clockwise rotation and clockwise reciprocation movement under optimum torque reverse (OTR) motion. Methods: New ProTaper Next X1 (n = 20) and X2 (n = 20) instruments were randomly divided into two subgroups (n = 10) based on kinematics (continuous rotation or OTR). The specimens were tested using a custom-made device with a non-tapered stainless-steel artificial canal measuring 19 mm in length, featuring a 6 mm radius and an 86-degree curvature. All instruments were tested with a lubricant at room temperature until a fracture occurred. The time to fracture and the length of the separated fragment were recorded. Subsequently, the fractured instruments were inspected under a scanning electron microscope for signs of cyclic fatigue failure, plastic deformation, and/or crack propagation. The subgroup comparisons for time to fracture and instrument length were performed using the independent samples t-test, with the level of statistical significance set at 0.05. Results: When using OTR movement, the ProTaper Next X1 increased the time to fracture from 52.9 to 125.8 s (p < 0.001), while the ProTaper Next X2 increased from 45.4 to 66.0 s (p < 0.001). No subgroup exhibited plastic deformations, but both showed dimpling marks indicative of cyclic fatigue as the primary mode of failure. Additionally, OTR movement resulted in more metal alloy microcracks. Conclusions: The use of OTR motion extended the lifespan of the tested instruments and resulted in a higher number of metal microcracks. This suggests that OTR motion helped to distribute the mechanical stress more evenly across the instrument, thereby relieving localized tension. As a result, it delayed the formation of a single catastrophic crack, enhancing the overall performance of the instruments during the experimental procedures.Keywords
This publication has 27 references indexed in Scilit:
- Influence of Kinematics on the Cyclic Fatigue Resistance of Replicalike and Original Brand Rotary InstrumentsJournal of Endodontics, 2020
- Mechanical Properties of a Novel Nickel-titanium Root Canal Instrument: Stationary and Dynamic TestsJournal of Endodontics, 2020
- Rotary Versus Reciprocation Root Canal Preparation: Initial Clinical Quality Assessment in a Novice Clinician CohortJournal of Endodontics, 2018
- The Effect of Temperature on Cyclic Fatigue of Nickel-titanium Rotary Endodontic InstrumentsJournal of Endodontics, 2017
- Evidence for Reduced Fatigue Resistance of Contemporary Rotary Instruments Exposed to Body TemperatureJournal of Endodontics, 2016
- Current Assessment of Reciprocation in Endodontic Preparation: A Comprehensive Review—Part II: Properties and EffectivenessJournal of Endodontics, 2015
- Quantitative evaluation of apically extruded debris with Twisted File Adaptive instruments in straight root canals: reciprocation with different angles, adaptive motion and continuous rotationInternational Endodontic Journal, 2015
- Deformation and fracture incidence of Reciproc instruments: a clinical evaluationInternational Endodontic Journal, 2014
- Rotary NiTi Instrument Fracture and its ConsequencesJournal of Endodontics, 2006
- Effect of temperature on collagen-dissolving ability of sodium hypochlorite endodontic irrigantOral Surgery, Oral Medicine, Oral Pathology, 1980