Comparison of a Wearable Tracker with Actigraph for Classifying Physical Activity Intensity and Heart Rate in Children
Open Access
- 25 July 2019
- journal article
- research article
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 16 (15) , 2663
Abstract
Introduction: To examine the validity and reliability of the Fitbit Charge HR (FCH), wrist-worn ActiGraph (AG) accelerometers were used for assessing the classification of physical activity (PA) into intensity categories in children. Methods: Forty-three children (n = 43) participated in the study. Each participant completed 3 min bouts of 12 PAs ranging from sedentary to vigorous intensity while simultaneously wearing FCH and AG on both hands, a Polar HR monitor, and a portable indirect calorimeter. Total time spent in different PA intensity levels measured by FCH and AG were compared to the indirect calorimetry. Results: The highest classification accuracy values of sedentary behavior was 81.1% for FCH. The highest classification (72.4%) of light intensity PA was observed with Crouter’s algorithm from the non-dominant wrist. Crouter’s algorithm also show the highest classification (81.8%) for assessing moderate to vigorous intensity PA compared to FCH (70.8%). Across the devices, a high degree of reliability was found in step measurements, ranging from an intra-class correlation (ICC) = 0.92 to an ICC = 0.94. The reliability of the AG and the FCH showed high agreement for each variable. Conclusion: The FCH shows better validity for estimating sedentary behavior and similar validity for assessing moderate to vigorous PA compared to the research-grade monitor. Across the devices, the reliability showed the strongest association.Keywords
Funding Information
- This research was funded by the National Research Foundation of Korea, Korean Government. (NRF-2014S1A2A1A01027966)
This publication has 39 references indexed in Scilit:
- Validation of the Fitbit One activity monitor device during treadmill walkingJournal of Science and Medicine in Sport, 2014
- Low validity of the Sensewear Pro3 activity monitor compared to indirect calorimetry during simulated free living in patients with osteoarthritis of the hipBMC Musculoskeletal Disorders, 2014
- Detection of Physical Activity Types Using Triaxial AccelerometersJournal of Physical Activity and Health, 2014
- Validity of the ActiGraph GT1M during walking and cyclingJournal of Sports Sciences, 2013
- Comparison of steps and energy expenditure assessment in adults of Fitbit Tracker and Ultra to the Actical and indirect calorimetryJournal of Medical Engineering & Technology, 2013
- Validation of Dual Energy X-Ray Absorptiometry Measures of Abdominal Fat by Comparison with Magnetic Resonance Imaging in an Indian PopulationPLOS ONE, 2012
- Accuracy of the SenseWear Armband™ during ErgocyclingInternational Journal of Sports Medicine, 2011
- A comprehensive evaluation of commonly used accelerometer energy expenditure and MET prediction equationsEuropean Journal of Applied Physiology, 2010
- Validation of the COSMED K4 b2 Portable Metabolic SystemInternational Journal of Sports Medicine, 2001
- Validation of the Polar Heart Rate Monitor for Assessing Heart Rate During Physical and Mental StressJournal of Psychophysiology, 2000