Background:: Organic solvents play an indispensable role in most of the radiopharmaceutical production stages. It is almost impossible to remove them entirely in the final formulation of the product. Objective:: In this presented work, an analytical method by gas chromatography coupled with flame ionization detection (GC-FID) has been developed to determine organic solvents in radiopharmaceutical samples. The effect of injection hold time, temperature variation in the injection port, and the column temperature on the analysis time and resolution (R ≥ 1.5) of ethanol and acetonitrile were studied extensively. Methods:: The experimental conditions were optimized with the aid of further statistical analysis; thence, the proposed method was validated following the International Council for Harmonisation (ICH) Q2 (R1) guideline. Results:: The proposed analytical method surpassed the acceptance criteria including the linearity > 0.990 (correlation coefficient of R2), precision < 2%, LOD, and LOQ, accuracy > 90% for all solvents. The separation between ethanol and acetonitrile was acceptable with a resolution R > 1.5. Further statistical analysis of Oneway ANOVA revealed that the increment in injection holding time and variation of temperature at the injection port did not significantly affect the analysis time. Nevertheless, the variation in injection port temperature substantially influenced the resolution of ethanol and acetonitrile peaks (p < 0.05). Conclusion:: The proposed analytical method has been successfully implemented to determine the organic solvent in the [18F]fluoro-ethyl-tyrosine ([18F]FET), [18F]fluoromisonidazole ([18F]FMISO), and [18F]fluorothymidine ([18F]FLT).Keywords
Funding Information
- Universiti Putra Malaysia (9580700)
This publication has 22 references indexed in Scilit:
- 18F-Labeled Peptides: The Future Is BrightMolecules, 2014
- A New Dimension in Separation Science: Comprehensive Two‐Dimensional Gas ChromatographyAngewandte Chemie International Edition, 2012
- Improved quality control of [18F]fluoromethylcholineNuclear Medicine and Biology, 2011
- Methods for the determination of limit of detection and limit of quantitation of the analytical methodsChronicles of Young Scientists, 2011
- A generic static headspace gas chromatography method for determination of residual solvents in drug substanceJournal of Chromatography A, 2010
- Basics and principles of radiopharmaceuticals for PET/CTEuropean Journal of Radiology, 2010
- Residual solvent analysis by gas chromatography in radiopharmaceutical formulations containing up to 12% ethanolNuclear Medicine and Biology, 2006
- Validation of a generic analytical procedure for determination of residual solvents in drug substancesJournal of Pharmaceutical and Biomedical Analysis, 2004
- Establishment of a Knowledge Base for Prescreening Residual Solvents in PharmaceuticalsChromatographia, 2004
- Residual solvents in pharmaceutical products: acceptable limits, influences on physicochemical properties, analytical methods and documented valuesEuropean Journal of Pharmaceutics and Biopharmaceutics, 1997