Safety and Performance of a System Specifically Designed for Selective Site Pacing
Authors:
- Francesco ZanonFZFrancesco Zanon
- Jennifer ComissoJCJennifer Comisso
- Annamaria VarbaroAVAnnamaria Varbaro
- Alessandra DenaroADAlessandra Denaro
- 11 November 2010
- journal article
- clinical trial
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 34 (3) , 339-347
Abstract
Introduction: In the right ventricle, selective site pacing (SSP) has been shown to avoid detrimental hemodynamic effects induced by right ventricular apical pacing and, in the right atrium, to prevent the onset of atrial fibrillation and to slow down disease progression. The purpose of our multicenter observational study was to describe the use of a transvenous 4‐French catheter‐delivered lead for SSP in the clinical practice of a large number of centers. Methods: We enrolled 574 patients in whom an implantable device was indicated. In all patients, SSP was achieved by using the Select Secure System™ (Medtronic Inc., Minneapolis, MN, USA). Results: In 570 patients, the lead was successfully implanted. In 125 patients, atrial SSP was performed: in 75 (60%) the lead was placed in the interatrial septum, in 31 (25%) in the coronary sinus ostium, and in 19 (15%) in the Bachman bundle. Ventricular SSP was undertaken in 138 patients: in 105 (76%) the high septal right ventricular outflow tract (RVOT) position was paced, in seven (5%) the high free‐wall RVOT, in 25 (18%) the low septal RVOT, and in one (1%) the low free‐wall RVOT. In the remaining 307 patients, the His zone was paced: in 87 (28%) patients, direct His‐bundle pacing and in 220 (72%) patients para‐hisian pacing was achieved. Adequate pacing parameters and a lead‐related complication rate of 2.6% were recorded during a follow‐up of 20 ± 10 months. Conclusions: Our results demonstrated that many sites, in the right atrium, in the right ventricle, and in His‐bundle region, can be paced using the Select Secure System™. (PACE 2011; 34:339–347)Keywords
This publication has 27 references indexed in Scilit:
- Direct His bundle pacing preserves coronary perfusion compared with right ventricular apical pacing: a prospective, cross-over mid-term studyEP Europace, 2008
- Evidence of left ventricular dyssynchrony resulting from right ventricular pacing in patients with severely depressed left ventricular ejection fractionEP Europace, 2007
- A Feasible Approach for Direct His‐Bundle Pacing Using a New Steerable Catheter to Facilitate Precise Lead PlacementJournal of Cardiovascular Electrophysiology, 2006
- Effect of chronic right ventricular apical pacing on left ventricular functionThe American Journal of Cardiology, 2005
- Heart failure hospitalization is more common in pacemaker patients with sinus node dysfunction and a prolonged paced QRS durationHeart Rhythm, 2005
- Selective Site Pacing:Pacing and Clinical Electrophysiology, 2004
- Direct His‐Bundle Pacing:Pacing and Clinical Electrophysiology, 2004
- A randomized comparison ofatrial and dual-chamber pacing in177 consecutive patients with sick sinus syndromeJACC, 2003
- Adverse Effect of Ventricular Pacing on Heart Failure and Atrial Fibrillation Among Patients With Normal Baseline QRS Duration in a Clinical Trial of Pacemaker Therapy for Sinus Node DysfunctionCirculation, 2003
- ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices: Summary ArticleCirculation, 2002