Subsegmental Pulmonary Emboli: Improved Detection with Thin-Collimation Multi–Detector Row Spiral CT
Authors:
- U. Joseph SchoepfUSU. Joseph Schoepf
- Nicolaus HolzknechtNHNicolaus Holzknecht
- Thomas K. HelmbergerTHThomas K. Helmberger
- Alexander CrispinACAlexander Crispin
- Cheng HongCHCheng Hong
- Christoph R. BeckerCBChristoph R. Becker
- Maximilian F. ReiserMRMaximilian F. Reiser
Top Cited Papers
- 1 February 2002
- journal article
- research article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 222 (2) , 483-490
Abstract
To compare different reconstruction thicknesses of thin-collimation multi-detector row spiral computed tomographic (CT) data sets of the chest for the detection of subsegmental pulmonary emboli. A multi-detector row spiral CT protocol for the diagnosis of pulmonary embolism was used that consisted of scanning the entire chest with 1-mm collimation within one breath hold. In 17 patients with central pulmonary embolism, the raw data were used to perform reconstructions with 1-mm, 2-mm, and 3-mm section thicknesses. For each set of images, each subsegmental artery was independently graded by three radiologists as open, containing emboli, or indeterminate. For the rate of detection of emboli in subsegmental pulmonary arteries, use of the 1-mm section width yielded an average increase of 40% when compared with the use of 3-mm-thick sections (P <.001) and of 14% when compared with the use of 2-mm-thick sections (P =.001). With the use of 1-mm sections versus 3-mm sections, the number of indeterminate cases decreased by 70% (P =.001). Interrater agreement was substantially better with the use of 1-mm and 2-mm sections than with the use of 3-mm sections. For the diagnosis of subsegmental pulmonary emboli at multi-detector row CT, the use of 1-mm section widths results in substantially higher detection rates and greater agreement between different readers than the use of thicker sections.Keywords
This publication has 27 references indexed in Scilit:
- Multislice Helical CT of Focal and Diffuse Lung DiseaseAmerican Journal of Roentgenology, 2001
- Pulmonary Embolism: Comprehensive Diagnosis by Using Electron-Beam CT for Detection of Emboli and Assessment of Pulmonary Blood FlowRadiology, 2000
- Deep Venous Thrombosis: Detection by Using Indirect CT VenographyRadiology, 2000
- Spiral Computed Tomography Is Comparable to Angiography for the Diagnosis of Pulmonary EmbolismAmerican Journal of Respiratory and Critical Care Medicine, 2000
- Combined CT Venography and Pulmonary Angiography in Suspected Thromboembolic DiseaseAmerican Journal of Roentgenology, 2000
- Reassessment of Pulmonary Angiography for the Diagnosis of Pulmonary Embolism: Relation of Interpreter Agreement to the Order of the Involved Pulmonary Arterial BranchRadiology, 1999
- Effect of anatomic distribution of pulmonary emboli on interobserver agreement in the interpretation of pulmonary angiography.American Journal of Roentgenology, 1998
- Correlation of diagnostic imaging and subsequent autopsy findings in patients with pulmonary embolism.American Journal of Roentgenology, 1998
- Detection of pulmonary embolism in patients with unresolved clinical and scintigraphic diagnosis: helical CT versus angiography.American Journal of Roentgenology, 1995
- Value of the Ventilation/Perfusion Scan in Acute Pulmonary EmbolismJAMA, 1990