Reference-Free Calibration for Wearable Core Body Temperature Sensor Based on Single-Heat-Flux Method
Open Access
- 30 July 2024
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 8 (9) , 1-4
Abstract
Core body temperature (CBT) is one of the useful physiological indicators that are linked to physiological changes. Wearable sensors are expected to be developed to monitor CBT easily during activities. A single-heat-flux method is one of the noninvasive techniques that estimate CBT by measuring heat flow changes near the skin with temperature sensors. The method requires calibrating parameters for estimating CBT in advance by comparing them with reference values obtained through another method. The invasive measurement method is generally used to obtain the reference values, which poses a challenge in terms of measurement burden. Here, we propose a new calibration method that does not require acquiring reference values. This method identifies calibration parameters based on the temperature history after the measurement probe is attached. It has been numerically and experimentally confirmed that the estimation accuracy by the method is equivalent to that of a general-purpose electronic thermometer. This outcome decreases the measurement workload in CBT measurement using the single-heat-flux method and significantly enhances its usability.Keywords
This publication has 26 references indexed in Scilit:
- Gastrointestinal function following endurance exercise under different environmental temperaturesEuropean Journal of Applied Physiology, 2024
- Heat flux systems for body core temperature assessment during exerciseJournal of Thermal Biology, 2023
- Validity of a wearable core temperature estimation system in heat using patch-type sensors on the chestJournal of Thermal Biology, 2022
- Climate Change and Heat Exposure: Impact on Health in Occupational and General Populations2019
- Subsurface investigation of the surface modification of polydimethylsiloxane by 172‐nm vacuum ultraviolet irradiation using ToF‐SIMS and VUV spectrometrySurface and Interface Analysis, 2018
- Body temperature and its regulationAnaesthesia & Intensive Care Medicine, 2014
- The effect of skin temperature on performance during a 7.5-km cycling time trialEuropean Journal of Applied Physiology, 2012
- Development of a new method for the noninvasive measurement of deep body temperature without a heaterMedical Engineering & Physics, 2009
- A non-invasive device to continuously determine heat strain in humansJournal of Thermal Biology, 2008
- Effects of humid heat exposure on sleep, thermoregulation, melatonin, and microclimateJournal of Thermal Biology, 2004