Calibration of EUV 2D photoresist simulation parameters for accurate predictive modeling

Authors:

Abstract
In this work simulation parameters are developed for Shipley EUV-2D photoresist under exposure at 13.4nm. Baseline parameter values are determined from theory and experiment. The simulation parameters were tuned from these values using a commercial automatic parameter optimisation software to match simulation results to experimental lithographic data generated using the ETS Set-2 projection optics in the subfield exposure station (SES). In an attempt to maximise parameter accuracy the experimental data set used included 4 different feature sizes and known non-idealities of the exposure set-up were accounted for (mask errors, lens aberrations and metrology bias). The resulting model described the experimental data very well with only a low level of residual error.