Dosimetric accuracy of a deterministic radiation transport based 192Ir brachytherapy treatment planning system. Part III. Comparison to Monte Carlo simulation in voxelized anatomical computational models
Authors:
- K. ZourariKZK. Zourari
- E. PantelisEPE. Pantelis
- A. MoutsatsosAMA. Moutsatsos
- L. SakelliouLSL. Sakelliou
- E. GeorgiouEGE. Georgiou
- P. KaraiskosPKP. Karaiskos
- P. PapagiannisPPP. Papagiannis
- 18 December 2012
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 40 (1) , 011712
Abstract
Purpose:: To compare TG43‐based and Acuros deterministic radiation transport‐based calculations of the BrachyVision treatment planning system (TPS) with corresponding Monte Carlo (MC) simulation results in heterogeneous patient geometries, in order to validate Acuros and quantify the accuracy improvement it marks relative to TG43.Methods:: Dosimetric comparisons in the form of isodose lines, percentage dose difference maps, and dose volume histogram results were performed for two voxelized mathematical models resembling an esophageal and a breast brachytherapy patient, as well as an actual breast brachytherapy patient model. The mathematical models were converted to digital imaging and communications in medicine (DICOM) image series for input to the TPS. The MCNP5 v.1.40 general‐purpose simulation code input files for each model were prepared using information derived from the corresponding DICOM RT exports from the TPS.Results:: Comparisons of MC and TG43 results in all models showed significant differences, as reported previously in the literature and expected from the inability of the TG43 based algorithm to account for heterogeneities and model specific scatter conditions. A close agreement was observed between MC and Acuros results in all models except for a limited number of points that lay in the penumbra of perfectly shaped structures in the esophageal model, or at distances very close to the catheters in all models.Conclusions:: Acuros marks a significant dosimetry improvement relative to TG43. The assessment of the clinical significance of this accuracy improvement requires further work. Mathematical patient equivalent models and models prepared from actual patient CT series are useful complementary tools in the methodology outlined in this series of works for the benchmarking of any advanced dose calculation algorithm beyond TG43.Keywords
This publication has 19 references indexed in Scilit:
- The dosimetric impact of heterogeneity corrections in high-dose-rate 192Ir brachytherapy for cervical cancer: Investigation of both conventional Point-A and volume-optimized plansBrachytherapy, 2012
- Report of the Task Group 186 on model‐based dose calculation methods in brachytherapy beyond the TG‐43 formalism: Current status and recommendations for clinical implementationMedical Physics, 2012
- Impact of Heterogeneity-Based Dose Calculation Using a Deterministic Grid-Based Boltzmann Equation Solver for Intracavitary BrachytherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2012
- Dosimetric accuracy of a deterministic radiation transport based brachytherapy treatment planning system. Part II: Monte Carlo and experimental verification of a multiple source dwell position plan employing a shielded applicatorMedical Physics, 2011
- Comparison of organ doses for patients undergoing balloon brachytherapy of the breast with HDR or electronic sources using Monte Carlo simulations in a heterogeneous human phantoma)Medical Physics, 2010
- Dosimetric accuracy of a deterministic radiation transport based brachytherapy treatment planning system. Part I: Single sources and bounded homogeneous geometriesMedical Physics, 2010
- RPI-AM and RPI-AF, a pair of mesh-based, size-adjustable adult male and female computational phantoms using ICRP-89 parameters and their calculations for organ doses from monoenergetic photon beamsPhysics in Medicine & Biology, 2009
- A CT‐based analytical dose calculation method for HDR brachytherapyMedical Physics, 2009
- Development of a scatter correction technique and its application to HDR I192r multicatheter breast brachytherapyMedical Physics, 2009
- The effect of finite patient dimensions and tissue inhomogeneities on dosimetry planning of 192Ir HDR breast brachytherapy: A Monte Carlo dose verification studyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2005