Automated impedance manometry analysis as a method to assess esophageal function
- 22 January 2014
- journal article
- research article
- Published by Wiley in Neurogastroenterology & Motility
- Vol. 26 (5) , 636-645
Abstract
Background: Diagnostic evaluation of non‐achalasia esophageal dysphagia remains challenging because of a lack of a clear relationship between symptoms, esophageal contraction patterns, and esophageal bolus flow. This study evaluates a novel approach to pressure‐impedance analysis called automated impedance manometry (AIM) analysis in relation to bolus characteristics, Chicago classification metrics, bolus perception, and dysphagia.Methods: AIM analysis was performed on esophageal high resolution manometry‐impedance recordings from 12 healthy controls and 15 patients with dysphagia. In each subject, 10 liquid, 10 semisolid, and 10 solid swallows were analyzed using AIMplot software.Key Results: This study demonstrated that (i) esophageal pressure‐flow parameters differ with bolus type (liquid, semisolid, and solids), (ii) impedance at peak pressure parameter can discriminate normal from dysphagic subjects with high accuracy on a cut‐off threshold at 2400 Ohms (kappa 0.77, sensitivity 0.83, and specificity 0.93), and (iii) nadir impedance and impedance at peak pressure highly correlate with perception of esophageal bolus flow (r = −0.65, p = 0.02; r = −0.70, p = 0.01 resp).Conclusions & Inferences: This study presents novel esophageal pressure‐flow variables in control subjects and in a cohort of patients with dysphagia. These variables are altered in relation to bolus consistency and can discriminate between subjects with and without symptoms of dysphagia. For the first time, we present high resolution esophageal pressure‐flow variables that accurately link in with patient perception of esophageal bolus hold up.Keywords
This publication has 18 references indexed in Scilit:
- Chicago classification criteria of esophageal motility disorders defined in high resolution esophageal pressure topography1Neurogastroenterology & Motility, 2012
- A Method to Objectively Assess Swallow Function in Adults With Suspected AspirationGastroenterology, 2011
- An audit of combined multichannel intraluminal impedance manometry in the assessment of dysphagiaJournal of Gastroenterology and Hepatology, 2011
- Normative values and inter-observer agreement for liquid and solid bolus swallows in upright and supine positions as assessed by esophageal high-resolution manometryNeurogastroenterology & Motility, 2011
- Impact of nadir lower oesophageal sphincter pressure on bolus clearance assessed by combined manometry and multi‐channel intra‐luminal impedance measurementNeurogastroenterology & Motility, 2009
- Oesophageal high-resolution manometry: moving from research into clinical practiceGut, 2008
- Quantifying esophageal peristalsis with high-resolution manometry: a study of 75 asymptomatic volunteersAmerican Journal of Physiology-Gastrointestinal and Liver Physiology, 2006
- Quantifying EGJ morphology and relaxation with high-resolution manometry: a study of 75 asymptomatic volunteersAmerican Journal of Physiology-Gastrointestinal and Liver Physiology, 2006
- Assessment of oesophageal motor function using combined perfusion manometry and multi‐channel intra‐luminal impedance measurement in normal subjectsNeurogastroenterology & Motility, 2005
- High‐resolution manometry predicts the success of oesophageal bolus transport and identifies clinically important abnormalities not detected by conventional manometryNeurogastroenterology & Motility, 2004