Abstract
Engineering critical assessment (ECA) is used as a procedure to evaluate the integrity of an engineering structure with flaws. To this end, ECA requires reliable fracture toughness values such as J-integral and CTOD. Ideal fracture toughness data can be obtained from an engineering structure, but may be impossible depending on the operating conditions. Appendix J of the BS 7910 provides a procedure for estimating fracture toughness values from appropriate Charpy impact test data. However, the correlation between Charpy impact energy and fracture toughness is highly conservative because they are not based on a theoretical background. In this regard, the revised BS 7910:2019 provides improved fracture toughness values by applying the yield strength and the Charpy upper shelf energy. The target of this study was to validate the master curve approach in the revised BS 7910 for groove shapes and the sample locations of impact tests. For that purpose, the master curves were compared in terms of the reference temperature obtained from Charpy impact energy data according to BS 7910:2013 and the modified BS 7910:2019. The revised master curve approach resulted in less conservative fracture toughness values. However, there were cases where BS 7910 and modified BS 7910 overestimated the fracture toughness compared to values using CTOD data. Further study of the master curve approach is needed, considering various heat inputs, groove shapes, and welding processes.
Funding Information
  • National Research Foundation of Korea (2017R1D1A1B03035811)
  • Ministry of Education
  • Ministry of Science and ICT (2011-0030013)

This publication has 1 reference indexed in Scilit: