Abstract
The Angioseal hemostatic device is currently in widespread use for arterial closure after both diagnostic and interventional procedures. Resticking of the artery in which an Angioseal device has been placed has been discouraged for up to 90 days after the initial device placement because of theoretical concerns of disruption or dislodgment of the hemostatic plug. However, no data are available to address this concern. We evaluated the incidence of vascular complications following restick of the artery in which an Angioseal device had been deployed ≤ 90 days previously in 181 patients. Restick occurred 1–7 days after device placement in 80 patients, 8–30 days in 34 patients, and 31–90 days in 66 patients. There were no major bleeding, vascular repair, vessel occlusion, or embolizations. Three large hematomas (1.7%) were noted. These data suggest that restick can be performed safely after initial Angioseal deployment. Cathet Cardiovasc Intervent 2003;58:181–184.Keywords
This publication has 15 references indexed in Scilit:
- Early clinical experience with the 6 French Angio‐Seal™ device: Immediate closure of femoral puncture sites after diagnostic and interventional coronary proceduresCatheterization and Cardiovascular Interventions, 2001
- The 6Fr angio-seal arterial closure device: results from a multimember prospective registryThe American Journal of Cardiology, 2001
- The Angio-Seal™ hemostatic puncture closure deviceHerz, 1999
- Efficacy and Safety of a Hemostatic Puncture Closure Device With Early Ambulation After Coronary AngiographyThe American Journal of Cardiology, 1998
- Immediate arterial hemostasis after cardiac catheterization: Initial experience with a new puncture closure deviceCatheterization and Cardiovascular Diagnosis, 1994
- A multicenter randomized trial comparing a percutaneous collagen hemotasis device with conventional manual compression after diagnostic angiography and angioplastyJACC, 1993
- A new hemostatic puncture closure device for the immediate sealing of arterial puncture sitesThe American Journal of Cardiology, 1993
- Collagen application for sealing of arterial puncture sites in comparison to pressure dressing: A randomized trialCatheterization and Cardiovascular Diagnosis, 1992
- Peripheral vascular complications after conventional and complex percutaneous coronary interventional proceduresThe American Journal of Cardiology, 1992
- Probable Inference, the Law of Succession, and Statistical InferenceJournal of the American Statistical Association, 1927