Temperature Increase and Damage Extent at Retinal Pigment Epithelium Compared between Continuous Wave and Micropulse Laser Application
Open Access
Abstract
Continuous wave (CW) and microsecond pulse (MP) laser irradiations were compared regarding cell damage and laser-induced temperature rise at retinal pigment epithelium (RPE). The RPE of porcine RPE-choroid-sclera explants was irradiated with a 577 nm laser in CW or MP mode (5% or 15% duty cycle (DC)) for 20 ms or 200 ms at an average laser power of 20–90 mW. Cell viability was investigated with calcein-AM staining. Optoacoustic (OA) technique was employed for temperature measurement during irradiation. For 200 ms irradiation, the dead cell area (DCA) increased linearly (≈1600 µm2/mW) up to the average power of 40 mW for all modes without significant difference. From 50 mW, the increase of DCA of MP-5% significantly dropped to 610 µm2/mW (p < 0.05), likely due to the detected microbubble formation. OA temperature measurement showed a monotonic temperature increase in CW mode and a stepwise increase in MP mode, but no significant difference in the average temperature increase at the same average power, consistent with the temperature modeling. In conclusion, there is no difference in the average temperature rise between CW and MP modes at the same average power regardless of DC. At lower DC, however, more caution is required regarding mechanical damage due to microbubble formation.Keywords
This publication has 40 references indexed in Scilit:
- Real-time temperature determination during retinal photocoagulation on patientsJournal of Biomedical Optics, 2012
- Spatially correlated microthermography maps threshold temperature in laser-induced damageJournal of Biomedical Optics, 2011
- Subthreshold Micropulse Diode Laser Photocoagulation for Diabetic Macular Edema in Japanese PatientsAmerican Journal of Ophthalmology, 2010
- Dynamics of retinal photocoagulation and ruptureJournal of Biomedical Optics, 2009
- Self-limited growth of laser-induced vapor bubbles around single microabsorbersApplied Physics Letters, 2008
- Noninvasive optoacoustic online retinal temperature determination during continuous-wave laser irradiationJournal of Biomedical Optics, 2006
- RPE Damage Thresholds and Mechanisms for Laser Exposure in the Microsecond-to-Millisecond Time RegimenInvestigative Ophthalmology & Visual Science, 2005
- Selective targeting of the retinal pigment epithelium using an acousto-optic laser scannerJournal of Biomedical Optics, 2005
- Noninvasive optoacoustic temperature determination at the fundus of the eye during laser irradiationJournal of Biomedical Optics, 2004
- Theoretical Investigations of Laser Thermal Retinal InjuryHealth Physics, 1985