NPC Three-Level Inverter Open-Circuit Fault Diagnosis Based on Adaptive Electrical Period Partition and Random Forest
Authors:
Open Access
- 17 January 2020
- journal article
- research article
- Published by Wiley in Journal of Sensors
- Vol. 2020, 1-18
Abstract
Fault detection can increase the reliability and efficiency of power electronic converters employed in power systems. Among the converters in the power system, a Neutral Point Clamped (NPC) three-level inverter is most commonly used to drive electric motors. In this paper, a new approach for open-circuit fault detection and location of the NPC three-level inverter for a shifting process using a constant voltage-to-frequency ratio is proposed. In order to diagnose open-circuit fault in as short a time as possible, an adaptive electrical period partition (AEPP) algorithm is proposed to pick single electrical periods from real-time three-phase current signals. The Maximal Overlap Discrete Wavelet Transformation (MODWT) and Park’s Vector Modulus (PVM) are used for feature analysis and normalization of electrical period signals. The statistical characteristics of the electrical period signals are extracted, and a random forest model is constructed to realize the state classification. Compared with the traditional fault diagnosis method, the proposed algorithm finds fault locations quickly and accurately. The effectiveness and accuracy of the proposed algorithm are verified by experiments.Keywords
Funding Information
- National Key R&D Program of China (2017YFC0804401, 2017YFC0804400, BA2016017)
- National Key R&D Program of China (2017YFC0804401, 2017YFC0804400, BA2016017)
- Transformation Program of Scientific and Technological Achievements of Jiangsu Provence (2017YFC0804401, 2017YFC0804400, BA2016017)
This publication has 27 references indexed in Scilit:
- Neural Network Fault Diagnosis of Voltage Source Inverter under variable load conditions at different frequenciesMeasurement, 2016
- Multiscale Adaptive Fault Diagnosis Based on Signal Symmetry Reconstitution Preprocessing for Microgrid Inverter Under Changing Load ConditionIEEE Transactions on Smart Grid, 2016
- A Modified Level-Shifted PWM Strategy for Fault-Tolerant Cascaded Multilevel Inverters With Improved Power DistributionIEEE Transactions on Industrial Electronics, 2016
- A Novel Diagnostic Technique for Open-Circuited Faults of Inverters Based on Output Line-to-Line Voltage ModelIEEE Transactions on Industrial Electronics, 2016
- Feature Knowledge Based Fault Detection of Induction Motors Through the Analysis of Stator Current DataIEEE Transactions on Instrumentation and Measurement, 2016
- Fault diagnosis method based on FFT-RPCA-SVM for Cascaded-Multilevel InverterISA Transactions, 2016
- Real-Time IGBT Open-Circuit Fault Diagnosis in Three-Level Neutral-Point-Clamped Voltage-Source Rectifiers Based on Instant Voltage ErrorIEEE Transactions on Industrial Electronics, 2014
- Fault diagnostic algorithm for three‐level neutral point clamped AC motor drives, based on the average current Park's vectorIET Power Electronics, 2014
- Ageing and Failure Modes of IGBT Modules in High-Temperature Power CyclingIEEE Transactions on Industrial Electronics, 2011
- Voltage source inverter fault diagnosis in variable speed AC drives, by the average current Park's vector approach2003