Bone mineral density measurements derived from dual-layer spectral CT enable opportunistic screening for osteoporosis
Open Access
- 21 May 2019
- journal article
- research article
- Published by Springer Nature in European Radiology
- Vol. 29 (11) , 6355-6363
Abstract
Objective To investigate the in vivo applicability of non-contrast-enhanced hydroxyapatite (HA)-specific bone mineral density (BMD) measurements based on dual-layer CT (DLCT). Methods A spine phantom containing three artificial vertebral bodies with known HA densities was measured to obtain spectral data using DLCT and quantitative CT (QCT), simulating different patient positions and grades of obesity. BMD was calculated from virtual monoenergetic images at 50 and 200 keV. HA-specific BMD values of 174 vertebrae in 33 patients (66 ± 18 years; 33% women) were determined in non-contrast routine DLCT and compared with corresponding QCT-based BMD values. Results Examining the phantom, HA-specific BMD measurements were on a par with QCT measurements. In vivo measurements revealed strong correlations between DLCT and QCT (r = 0.987 [95% confidence interval, 0.963–1.000]; p < 0.001) and substantial agreement in a Bland–Altman plot. Conclusion DLCT-based HA-specific BMD measurements were comparable with QCT measurements in in vivo analyses. This suggests that opportunistic DLCT-based BMD measurements are an alternative to QCT, without requiring phantoms and specific protocols. Key Points • DLCT-based hydroxyapatite-specific BMD measurements show a substantial agreement with QCT-based BMD measurements in vivo. • DLCT-based hydroxyapatite-specific measurements are on a par with QCT in spine phantom measurements. • Opportunistic DLCT-based BMD measurements may be a feasible alternative for QCT, without requiring dedicated examination protocols or a phantom.Keywords
Funding Information
- European Research Council (ERC-StG-2014 637164)
- European Research Council (H2020, AdG 695045)
- Deutsche Forschungsgemeinschaft (Gottfried Wilhelm Leibniz program)
- Bundesministerium für Forschung, Technologie und Raumfahrt (13GW0072C)
This publication has 36 references indexed in Scilit:
- Dual-Energy CT–Based Monochromatic ImagingAmerican Journal of Roentgenology, 2012
- Osteoporosis Imaging: State of the Art and Advanced ImagingRadiology, 2012
- Does vertebral bone marrow fat content correlate with abdominal adipose tissue, lumbar spine bone mineral density, and blood biomarkers in women with type 2 diabetes mellitus?Journal of Magnetic Resonance Imaging, 2011
- Simultaneous screening for osteoporosis at CT colonography: Bone mineral density assessment using MDCT attenuation techniques compared with the DXA reference standardJournal of Bone and Mineral Research, 2011
- Health-related quality of life after vertebral or hip fracture: a seven-year follow-up studyBMC Musculoskeletal Disorders, 2009
- Longitudinal Trends in Use of Bone Mass Measurement Among Older Americans, 1999–2005Journal of Bone and Mineral Research, 2008
- Development of formulas for standardized DXA measurementsJournal of Bone and Mineral Research, 1995
- Two Postprocessing CT Techniques for Determining the Composition of Trabecular BoneInvestigative Radiology, 1987
- Dual-Energy Projection Radiography in the Evaluation of Femoral Neck Strength, Density, and MineralizationInvestigative Radiology, 1985
- A Postprocessing Dual Energy Technique for Vertebral CT DensitometryJournal of Computer Assisted Tomography, 1984