Automated estimation of regional mean transition times and radial velocities from cine magnetic resonance images: Evaluation in normal subjects
Open Access
- 1 July 2009
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 30 (1) , 236-242
Abstract
Purpose To assess regional ventricular function via an accurate and automated definition of functional parameters. Materials and Methods An automated method is proposed that estimates reliable regional normalized mean transition times (Fmc) and mean radial velocities (Vm) from cine images. This approach combines a quantitative parametric imaging method and an automated detection of the endocardial border, which is robust to the presence of papillary muscles and nonhomogeneities within the left ventricular cavity. Steady‐state free‐precession cine‐magnetic resonance imaging (MRI) of 36 healthy subjects was analyzed. Results The quality of the automated segmentation was assessed on a subgroup of 20 subjects by comparing the results with the manual contours traced by an expert. The comparison of functional parameters estimated consequently using the automated and the manual contours yielded (y = 0.959x + 0.016, R = 0.964) for Fmc and (y = 0.883x + 0.505, R = 0.935) for Vm. On the entire group, Fmc was equal to 0.392 ± 0.069 and Vm to 5.4 ± 2.3 cm/s. Increasing values of the temporal parameter from the apex to the base and larger values in the septal wall than in lateral wall were demonstrated and were in accordance with the physiology. Conclusion The proposed method ensures an automated and robust assessment of regional wall motion parameters, which could be clinically useful. J. Magn. Reson. Imaging 2009;30:236–242.Keywords
This publication has 19 references indexed in Scilit:
- Interobserver Variability in Assessing Segmental Function can be Reduced by Combining Visual Analysis of CMR Cine Sequences with Corresponding Parametric Images of Myocardial ContractionJournal of Cardiovascular Magnetic Resonance, 2007
- Evaluation of regional myocardial function using automated wall motion analysis of cine MR images: Contribution of parametric images, contraction times, and radial velocitiesJournal of Magnetic Resonance Imaging, 2007
- Analysis of Regional Left Ventricular Function by Cineventriculography, Cardiac Magnetic Resonance Imaging, and Unenhanced and Contrast-Enhanced EchocardiographyJACC, 2006
- Assessment of left ventricular contraction by parametric analysis of main motion (PAMM): theory and application for echocardiographyPhysics in Medicine & Biology, 2005
- Automated segmentation of the left ventricle in cardiac MRIMedical Image Analysis, 2004
- The Role of Still?Frame Parametric Imaging in Magnetic Resonance Assessment of Left Ventricular Wall Motion by Non?cardiologistsJournal of Cardiovascular Magnetic Resonance, 2004
- Three?Directional Myocardial Motion Assessed Using 3D Phase Contrast MRIJournal of Cardiovascular Magnetic Resonance, 2004
- Timing of cardiac contraction in humans mapped by high-temporal-resolution MRI tagging: early onset and late peak of shortening in lateral wallAmerican Journal of Physiology-Heart and Circulatory Physiology, 2004
- Automated cardiac MR image segmentation: theory and measurement evaluationMedical Engineering & Physics, 2002
- Steady‐state free precession magnetic resonance imaging of the heart: Comparison with segmented k‐space gradient‐echo imagingJournal of Magnetic Resonance Imaging, 2001