Development of Streptavidin Carrying Magnetic Nanoparticles and Their Applications in Electrochemical Nucleic Acid Sensor Systems
- 12 April 2007
- journal article
- research article
- Published by Wiley in Electroanalysis
- Vol. 19 (7-8) , 798-804
Abstract
The aim of this study is to investigate the applicability of streptavidin carrying magnetic nanoparticles in electrochemical nucleic acid sensor systems. The magnetite (Fe3O4) nanoparticles were prepared by co‐precipitation technique, and then they were coated with a carboxylic acid containing polymer layer. Streptavidin molecules were immobilized onto the surfaces of these magnetic nanoparticles (with two different average diameter of 125 and 225 nm) via these functional groups. An electrochemical nucleic acid sensor system composed of a disposable graphite sensor, pencil graphite electrode (PGE) and differential pulse voltammetry (DPV) was used for measurement of guanine oxidation signal observed at +1.0 V. In the hybridization tests biotinylated inosine substituted probe was immobilized onto the magnetic nanoparticles and hybridization with its complementary target at the surface of particles within the medium was exhibited successfully by using this electrochemical sensor system. For electrochemical detection of sequence specific DNA hybridization and its selectivity studies, the biotinylated hepatitis B Virus (HBV) wild type probe was immobilized onto the nanoparticles. The guanine oxidation signals were measured in the solutions containing no target, the complementary target, a single‐base mismatch target, and noncomplementary target oligonucleotides. A significant guanine oxidation signal (71 nA) was observed with the complementary target due to complete hybridization, while with single‐base mismatch target, the signal at the same conditions was quite low about 14 nA. However, in the case of the noncomplementary target, there was a low but observable mean signal about 9 nA (showing the nonspecific interaction). The detection limit (S/N=3) was found as 43.11 pmol/mL target concentration obtained in 20 min hybridization time.Keywords
This publication has 33 references indexed in Scilit:
- Direct DNA Hybridization at Disposable Graphite Electrodes Modified with Carbon NanotubesAnalytical Chemistry, 2006
- Genomagnetic assay based on label-free electrochemical detection using magneto-composite electrodesSensors and Actuators B: Chemical, 2006
- Echinomycin and cobalt-phenanthroline as redox indicators of DNA hybridization at gold electrodesFrontiers in Bioscience-Landmark, 2006
- Electrochemical genosensing of the interaction between the potential chemotherapeutic agent, cis-bis(3-aminoflavone)dichloroplatinum(II) and DNA in comparison with cis-DDPJournal of Pharmaceutical and Biomedical Analysis, 2005
- Label‐free DNA Hybridization Based on Coupling of a Heated Carbon Paste Electrode with Magnetic SeparationsElectroanalysis, 2004
- Nanoparticle-based electrochemical DNA detectionAnalytica Chimica Acta, 2003
- Electrochemical enzyme-linked immunoassay in a DNA hybridization sensorAnalytica Chimica Acta, 2002
- Peer Reviewed: Detecting DNA Hybridization and DamageAnalytical Chemistry, 2001
- Novel hybridization indicator methylene blue for the electrochemical detection of short DNA sequences related to the hepatitis B virusAnalytica Chimica Acta, 2000
- DNA Electrochemical Biosensor for the Detection of Short DNA Sequences Related to the Human Immunodeficiency VirusAnalytical Chemistry, 1996