Simple Resolution of Butylated Hydroxyanisole and n‐Propyl Gallate in Fatty Foods and Cosmetics Samples by Flow‐Injection Solid‐Phase Spectrophotometry
Authors:
- L.F. Capitán‐VallveyLCL.F. Capitán‐Vallvey
- M. C. ValenciaMVM. C. Valencia
- E. Arana NicolásENE. Arana Nicolás
- 1 June 2003
- journal article
- Published by Wiley in Journal of Food Science
- Vol. 68 (5) , 1595-1599
Abstract
A biparameter sensor using flow injection with solid‐phase spectrophotometry for the simultaneous determination of butylated hydroxyanisole (BHA) and n‐propyl gallate (n‐PG) in fatty foods and cosmetics is proposed. The method is based on different transient retentions of these antioxidants when carried with methanol‐water 30:70%, vol/vol, through a flow cell packed to a 25‐mm height with C 18 silica. Each antioxidant was determined by measuring its intrinsic absorbance at its residence time (40 s at 272 nm for n‐PG; 200 s at 288 nm for BHA; calibration: 5.0 to 300.0 μg/mL; RSD: 1.7%) by flow technique and diode‐array detector. Resolution of the BHA‐n‐PG mixture in ratios between 1:10 and 10:1 is possible.Keywords
This publication has 20 references indexed in Scilit:
- FLOW-THROUGH SENSOR FOR DETERMINATION OF BUTYLATED HYDROXYTOLUENE IN COSMETICSAnalytical Letters, 2002
- Synthetic antioxidants determination in lard and vegetable oils by the use of voltammetric methods on disk ultramicroelectrodesFood Research International, 2000
- Separation and Determination of Phenolic Antioxidants by HPLC with Surfactant/n-Propanol Mobile PhasesJournal of High Resolution Chromatography, 2000
- Voltammetric Behavior and Simultaneous Determination of the Antioxidants Propyl Gallate, Butylated Hydroxyanisole, and Butylated Hydroxytoluene in Acidic Acetonitrile-Water Medium Using PLS CalibrationElectroanalysis, 1998
- Continuous-flow determination of natural and synthetic antioxidants in foods by gas chromatographyAnalytica Chimica Acta, 1998
- Simultaneous kinetic determination of butylated hydroxyanisole and propyl gallate by coupling stopped-flow mixing technique and diode-array detectionAnalytica Chimica Acta, 1997
- Analysis of cosmetic products by gas chromatography/mass spectrometry and fast-atom bombardment mass spectrometry: when a combined approach is successfulRapid Communications in Mass Spectrometry, 1997
- Is my calibration linear?The Analyst, 1994
- Estimation of Performance Characteristics of an Analytical Method Using the Data Set Of The Calibration ExperimentAnalytical Letters, 1993
- Uses (proper and improper) of correlation coefficientsThe Analyst, 1988