Endobronchial ultrasound versus conventional transbronchial needle aspiration in the diagnosis of mediastinal lymphadenopathy: a meta-analysis
Open Access
- 5 October 2016
- journal article
- research article
- Published by Springer Nature in SpringerPlus
- Vol. 5 (1) , 1716
Abstract
Currently, whether endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is superior to conventional TBNA (cTBNA) in the diagnosis of mediastinal lymphadenopathy remains controversial. We undertook a meta-analysis of randomized controlled trials (RCTs) to evaluate the diagnostic yield of EBUS-TBNA versus cTBNA in the diagnosis of mediastinal lymphadenopathy, both in benign and malignant etiologies. Computer-based retrieval was performed on PubMed and EMBASE. The quality was evaluated according to the quality assessment of diagnostic accuracy studies-2, and Meta-Disc was adopted to perform meta-analysis. The pooled sensitivity, specificity, and diagnostic odds ratio (DOR) with 95 % confidence intervals (CIs) were calculated. The summary receiving operating characteristic curve as well as the areas under curve (AUC) was measured. Four studies with a total of 440 patients met the inclusion criteria. Our results showed that the pooled sensitivity was 0.90 (95 % CI 0.85–0.94) and 0.76 (95 % CI 0.68–0.82), pooled specificity was 0.75 (95 % CI 0.60–0.87) and 0.94 (95 % CI 0.86–0.98), DOR was 75.38 (95 % CI 16.38–346.97) and 108.17 (95 % CI 13.84–845.35), and AUC was 0.9339 and 0.9732 for EBUS-TBNA group and cTBNA group, respectively. Although EBUS-TBNA with a higher sensitivity performs better than cTBNA, there is lack of enough evidence regarding EBUS-TBNA being superior to cTBNA in the diagnosis of mediastinal lymphadenopathy. Considering the limitations of methodology and limited data, further robust RCTs are needed to verify the current findings and investigate the optimal choice in patients receiving TBNA.Keywords
Funding Information
- Science and Technology Bureau in the form of social development funding (XZZD1345)
This publication has 42 references indexed in Scilit:
- EBUS-TBNA Provides Highest RNA Yield for Multiple Biomarker Testing from Routinely Obtained Small Biopsies in Non-Small Cell Lung Cancer Patients - A Comparative Study of Three Different Minimal Invasive Sampling MethodsPLOS ONE, 2013
- QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy StudiesAnnals of Internal Medicine, 2011
- Learning curves for endobronchial ultrasound using cusum analysisThorax, 2010
- The value of endoscopic ultrasound after bronchoscopy to diagnose thoracic sarcoidosisEuropean Respiratory Journal, 2009
- Test performance of endobronchial ultrasound and transbronchial needle aspiration biopsy for mediastinal staging in patients with lung cancer: systematic review and meta-analysisThorax, 2009
- Endobronchial ultrasound-guided transbronchial needle aspiration for staging of lung cancer: A systematic review and meta-analysisEuropean Journal of Cancer, 2009
- Real-time endobronchial ultrasound guided transbronchial needle aspiration for sampling mediastinal lymph nodesThorax, 2006
- Measuring inconsistency in meta-analysesBMJ, 2003
- Quantifying heterogeneity in a meta‐analysisStatistics in Medicine, 2002
- Meta-analysis in clinical trialsControlled Clinical Trials, 1986