Sensitization Patterns to Cyanoacrylate‐Based Surgical Glues
Authors:
- Lucrezia BianchettiLBLucrezia Bianchetti
- Anna WalkerAWAnna Walker
- Ophelie MarchalOMOphelie Marchal
- Héloïse WüthrichHWHéloïse Wüthrich
- An GoossensAn Goossens
- Ella DendoovenEDElla Dendooven
- Olivier AertsOAOlivier Aerts
- Curdin ConradCCCurdin Conrad
- Michel GillietMGMichel Gilliet
- Teofila SeremetTSTeofila Seremet
Open Access
- 7 July 2025
- journal article
- Published by Wiley in Contact Dermatitis
- Vol. 93 (4) , 328-335
Abstract
Background: Surgical glues are increasingly used, offering advantages like reduced scarring and faster wound closure. However, they pose risks of localised and disseminated allergic contact dermatitis caused by cyanoacrylate monomers.Objectives: This study aims to evaluate sensitisation patterns to cyanoacrylate‐based surgical glues, the usefulness of testing with the commercially available ethyl cyanoacrylate, and cross‐reactions between cyanoacrylates and (meth)acrylates.Patients/Methods: Sixteen patients with suspected allergic contact dermatitis (ACD) from surgical adhesives were patch tested with the European Standard and Acrylate series (only containing ethyl cyanoacrylate) among other series, of whom 15 were tested with the surgical glues used. Clinical data, including demographics and surgical histories, were collected.Results: Fifteen patients (94%) tested positively to surgical glues, with 81% showing positive reactions to ethyl cyanoacrylate, to which the patient not tested to the glue “as is” also reacted. Three ethyl cyanoacrylate‐negative patients reacted to Dermabond Prineo. Exclusive sensitisation to ethyl cyanoacrylate was observed in eight patients, while five reacted to other (meth)acrylic compounds.Conclusions: Ethyl cyanoacrylate is a screening agent for surgical‐glue sensitised patients, but if negative, tape‐stripping‐modified patch testing, also with the glues, is indicated. Cross‐reactions can occur between cyanoacrylates and co‐reactions (concomitant sensitization) with certain (meth)acrylates. Primary sensitisation is particularly relevant in patients undergoing treatment with cyanoacrylate‐based glues for the first time, rather than because of previous exposure to other sources.Keywords
This publication has 24 references indexed in Scilit:
- Allergic Contact Dermatitis to Octyl Cyanoacrylate Skin Glue after Surgical Wound Closure: A Systematic ReviewDermatitis®, 2024
- Incidence of Skin Sensitivity Following Dermabond Application in Pediatric Orthopedic SurgeryJournal of Pediatric Orthopaedics, 2023
- Documented Contact Allergy Impacts Risk for Surgical Adhesive–Associated Contact Dermatitis after Shoulder ArthroplastyArthroscopy, Sports Medicine, and Rehabilitation, 2023
- Scratch Patch Testing to Dermabond in a Patient with Suspected Allergic Contact DermatitisDermatitis®, 2023
- Wound Complications Are Affected by Different Skin Closure Methods in Primary Hip and Knee ArthroplastyThe Journal of Arthroplasty, 2023
- Medical adhesive allergens: Retrospective analysis of cross-sectional data from the North American Contact Dermatitis Group, 2001-2018Journal of the American Academy of Dermatology, 2022
- Patch Testing Ingredients of Dermabond and Other Cyanoacrylate-Containing AdhesivesDermatitis®, 2019
- Allergic contact dermatitis to 2-octyl cyanoacrylate after surgical repair: Humidity as a potential factorJAAD Case Reports, 2017
- Surgery-Related Contact Dermatitis: A Review of Potential Irritants and AllergensThe Journal of Allergy and Clinical Immunology: In Practice, 2017
- Severe Allergic Contact Dermatitis to Dermabond Prineo, a Topical Skin Adhesive of 2-Octyl Cyanoacrylate Increasingly Used in Surgeries to Close WoundsDermatitis®, 2016