Disposable Nafion-Coated Single-Walled Carbon Nanotube Test Strip for Electrochemical Quantitative Determination of Acetaminophen in a Finger-Prick Whole Blood Sample
Open Access
- 26 August 2020
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 92 (19) , 13017-13024
Abstract
A disposable electrochemical test strip for quantitative point-of-care (POC) determination of acetaminophen (paracetamol) in plasma and finger-prick whole blood was fabricated. The industrially scalable dry transfer process of single-walled carbon nanotubes (SWCNT) and screen-printing of silver was combined to produce integrated electrochemical test-strips. Nafion coating stabilized the potential of the Ag reference electrode and enabled the selective detection in spiked plasma as well as in whole blood samples. The test strips were able to detect acetaminophen in small 40 µL samples with a detection limit of 0.8 µM and wide linear range from 1 µM to 2 mM, well within the required clinical range. After a simple 1:1 dilution of plasma and whole blood, quantitative detection with good recoveries of 79% in plasma and 74% in whole blood were achieved. These results strongly indicate that these electrodes can be used directly to determine the unbound acetaminophen fraction without the need for any additional steps. The developed test strip shows promise as a rapid and simple POC quantitative acetaminophen assay.Keywords
Funding Information
- Aalto-Yliopisto
- Orionin Tutkimussäätiö
- Tekes (211637, 2117731)
This publication has 52 references indexed in Scilit:
- The modern pharmacology of paracetamol: therapeutic actions, mechanism of action, metabolism, toxicity and recent pharmacological findingsInflammopharmacology, 2013
- Can finger‐prick sampling replace venous sampling to determine the pharmacokinetic profile of oral paracetamol?British Journal of Clinical Pharmacology, 2010
- Carbon‐nanotube film on plastic as transparent electrode for resistive touch screensJournal of the Society for Information Display, 2009
- Electrochemical study and flow injection analysis of paracetamol in pharmaceutical formulations based on screen-printed electrodes and carbon nanotubesAnalytica Chimica Acta, 2009
- Standard Operating Procedures for Serum and Plasma Collection: Early Detection Research Network Consensus Statement Standard Operating Procedure Integration Working GroupJournal of Proteome Research, 2008
- False positive acetaminophen concentrations in patients with liver injuryClinica Chimica Acta, 2008
- Acetaminophen‐induced acute liver failureHepatology, 2005
- Disposable Carbon Nanotube Modified Screen‐Printed Biosensor for Amperometric Detection of Organophosphorus Pesticides and Nerve AgentsElectroanalysis, 2004
- Problems associated with the thin-film Ag/AgCl reference electrode and a novel structure with improved durabilitySensors and Actuators B: Chemical, 1998
- Fabrication and Characterization of a Solid State Reference Electrode for Electroanalysis of Natural Waters with UltramicroelectrodesAnalytical Chemistry, 1997