The Effectiveness of Ultraviolet Smart D60 in Reducing Contamination of Flexible Fiberoptic Laryngoscopes
Authors:
Open Access
- 24 July 2023
- journal article
- research article
- Published by Wiley in The Laryngoscope
- Vol. 133 (12) , 3512-3519
Abstract
Objective: To compare the effectiveness of disinfection protocols utilizing a ultraviolet (UV) Smart D60 light system with Impelux™ technology with a standard Cidex ortho‐phthalaldehyde (OPA) disinfection protocol for cleaning flexible fiberoptic laryngoscopes (FFLs).Methods: Two hundred FFLs were tested for bacterial contamination after routine use, and another 200 FFLs were tested after disinfection with one of four methods: enzymatic detergent plus Cidex OPA (standard), enzymatic detergent plus UV Smart D60, microfiber cloth plus UV Smart D60, and nonsterile wipe plus UV Smart D60. Pre‐ and post‐disinfection microbial burden levels and positive culture rates were compared using Kruskal‐Wallis ANOVA and Fisher's two‐sided exact, respectively.Results: After routine use, approximately 56% (112/200) of FFLs were contaminated, with an average contamination level of 9,973.7 ± 70,136.3 CFU/mL. The standard reprocessing method showed no positive cultures. The enzymatic plus UV, microfiber plus UV, and nonsterile wipe plus UV methods yielded contamination rates of 4% (2/50), 6% (3/50), and 12% (6/50), respectively, with no significant differences among the treatment groups (p > 0.05). The pre‐disinfection microbial burden levels decreased significantly after each disinfection technique (p < 0.001). The average microbial burden recovered after enzymatic plus UV, microfiber plus UV, and nonsterile wipe plus UV were 0.40 CFU/mL ± 2, 0.60 CFU/mL ± 2.4, and 12.2 CFU/mL ± 69.5, respectively, with no significant difference among the treatment groups (p > 0.05). Micrococcus species (53.8%) were most frequently isolated, and no high‐concern organisms were recovered.Conclusion: Disinfection protocols utilizing UV Smart D60 were as effective as the standard chemical disinfection protocol using Cidex OPA.Level of Evidence: NA Laryngoscope, 133:3512–3519, 2023Keywords
This publication has 32 references indexed in Scilit:
- Room Decontamination with UV RadiationInfection Control & Hospital Epidemiology, 2010
- Evaluation of an automated ultraviolet radiation device for decontamination of Clostridium difficile and other healthcare-associated pathogens in hospital roomsBMC Infectious Diseases, 2010
- Evaluation of Ultraviolet C for Disinfection of Endocavitary Ultrasound Transducers Persistently Contaminated despite Probe CoversInfection Control & Hospital Epidemiology, 2010
- Prevention of disease transmission during flexible laryngoscopyAmerican Journal of Infection Control, 2007
- Evaluation of a new disinfection procedure for ultrasound probes using ultraviolet lightJournal of Hospital Infection, 2007
- Overview of Nosocomial Infections Caused by Gram-Negative BacilliClinical Infectious Diseases, 2005
- Nine episodes of anaphylaxis following cystoscopy caused by Cidex OPA (ortho-phthalaldehyde) high-level disinfectant in 4 patients after cytoscopyJournal of Allergy and Clinical Immunology, 2004
- Reprocessing endoscopes: United States perspectiveJournal of Hospital Infection, 2004
- South African survey on disinfection techniques for the flexible nasopharyngoscopeThe Journal of Laryngology & Otology, 2003
- Disinfection of surgical instrumentsJournal of Hospital Infection, 1981