Nonrigid Motion Correction With 3D Image‐Based Navigators for Coronary MR Angiography
- 13 May 2016
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 77 (5) , 1884-1893
Abstract
Purpose: To develop a retrospective nonrigid motion‐correction method based on 3D image‐based navigators (iNAVs) for free‐breathing whole‐heart coronary magnetic resonance angiography (MRA).Methods: The proposed method detects global rigid‐body motion and localized nonrigid motion from 3D iNAVs and compensates them with an autofocusing algorithm. To model the global motion, 3D rotation and translation are estimated from the 3D iNAVs. Two sets of localized nonrigid motions are obtained from deformation fields between 3D iNAVs and reconstructed binned images, respectively. A bank of motion‐corrected images is generated and the final image is assembled pixel‐by‐pixel by selecting the best focused pixel from this bank. In vivo studies with six healthy volunteers were conducted to compare the performance of the proposed method with 3D translational motion correction and no correction.Results: In vivo studies showed that compared to no correction, 3D translational motion correction and the proposed method increased the vessel sharpness by 13% ± 13% and 19% ± 16%, respectively. Out of 90 vessel segments, 75 segments showed improvement with the proposed method compared to 3D translational correction.Conclusion: We have developed a nonrigid motion‐correction method based on 3D iNAVs and an autofocusing algorithm that improves the vessel sharpness of free‐breathing whole‐heart coronary MRA. Magn Reson Med 77:1884–1893, 2017. © 2016 International Society for Magnetic Resonance in MedicineKeywords
This publication has 52 references indexed in Scilit:
- Self-Navigation with Compressed Sensing for 2D Translational Motion Correction in Free-Breathing Coronary MRI: A Feasibility StudyPLOS ONE, 2014
- Prospective respiratory motion correction for coronary MR angiography using a 2D image navigatorMagnetic Resonance in Medicine, 2012
- Respiratory self‐navigation for whole‐heart bright‐blood coronary MRI: Methods for robust isolation and automatic segmentation of the blood poolMagnetic Resonance in Medicine, 2011
- Whole‐heart coronary MR angiography with 2D self‐navigated image reconstructionMagnetic Resonance in Medicine, 2011
- Motion in Cardiovascular MR ImagingRadiology, 2009
- Free‐breathing whole‐heart coronary MRA with 3D radial SSFP and self‐navigated image reconstructionMagnetic Resonance in Medicine, 2005
- Novel prospective respiratory motion correction approach for free‐breathing coronary MR angiography using a patient‐adapted affine motion modelMagnetic Resonance in Medicine, 2003
- Prospective navigator correction of image position for coronary MR angiography.Radiology, 1997
- Navigator-echo-based real-time respiratory gating and triggering for reduction of respiration effects in three-dimensional coronary MR angiography.Radiology, 1996
- Adaptive technique for high-definition MR imaging of moving structures.Radiology, 1989