Five-year long-term outcomes of intrastromal corneal ring segment implantation using the manual technique for keratoconus management
Authors:
- 12 November 2020
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 47 (6) , 713-721
Abstract
Purpose: To evaluate the long-term effectiveness, safety, and stability of Ferrara-type intrastromal corneal ring segments (ICRS) by manual surgery implantation in patients with keratoconus. Setting: Ophthalmology Department, Hospital de Braga, Braga, Portugal. Design: Retrospective cohort study. Methods: This study included 124 eyes that had ICRS implantation using the manual technique with a follow-up of 5 years. Uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA), subjective refraction, keratometry, aberrometry, and pachymetry maps were evaluated preoperatively and at 6 months, 1 year, and 5 years postoperatively. A secondary analysis of all variables was performed comparing 2 subgroups of patients: a group younger than 30 years and a group of 30 years or older. Results: At 5 years, both mean UDVA and CDVA improved significantly (P < .0001) from a preoperative value of 0.91 ± 0.36 to 0.46 ± 0.32 logMAR and 0.40 ± 0.27 to 0.22 ± 0.20 logMAR, respectively. Spherical equivalent, refractive cylinder, and all topography values significantly decreased postoperatively (P < .0001). No regression was observed in any visual or topographic parameter during the entire follow-up. Regarding the subgroup analysis, both younger and older patients demonstrated similar and stable results from the preoperative to the 5-year visit, except for minimum pachymetry value change over time. Conclusions: Ferrara-type ICRS implantation significantly improved visual acuity, refractive error, and topographic values; the improvement was stable throughout a 5-year follow-up period. This study confirms that ICRS implantation surgery for keratoconus is a stable procedure in a long-term follow-up, regardless of the preoperative patient's age.Keywords
This publication has 24 references indexed in Scilit:
- Intrastromal Corneal Ring Segments Implantation in Patients With Keratoconus: 10-Year Follow-UpJournal of Refractive Surgery, 2014
- Outcomes of intrastromal corneal ring segments for treatment of keratoconus: Five-year follow-up analysisJournal of Cataract & Refractive Surgery, 2013
- Intrastromal corneal ring segment implantation in paracentral keratoconus with coincident topographic and coma axisJournal of Cataract & Refractive Surgery, 2012
- Intrastromal corneal ring segments and posterior chamber phakic intraocular lens implantation for keratoconus correctionJournal of Cataract & Refractive Surgery, 2011
- A randomised, prospective study to investigate the efficacy of riboflavin/ultraviolet A (370 nm) corneal collagen cross-linkage to halt the progression of keratoconusBritish Journal of Ophthalmology, 2011
- Comparison of mechanical and femtosecond laser tunnel creation for intrastromal corneal ring segment implantation in keratoconusJournal of Cataract & Refractive Surgery, 2010
- Long-term follow-up of intrastromal corneal ring segments in keratoconusJournal of Cataract & Refractive Surgery, 2009
- Long-term Follow-up of Intacs in KeratoconusAmerican Journal of Ophthalmology, 2007
- Longitudinal Changes in Visual Acuity in KeratoconusInvestigative Ophthalmology & Visual Science, 2006
- KeratoconusSurvey of Ophthalmology, 1998