The Modified Super-Ellipsoid Yield Criterion for Human Trabecular Bone
Authors:
- 1 December 2004
- journal article
- research article
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 126 (6) , 677-684
Abstract
Despite the importance of multiaxial failure of trabecular bone in many biomechanical applications, to date no complete multiaxial failure criterion for human trabecular bone has been developed. By using experimentally validated nonlinear high-resolution, micro-mechanical finite-element models as a surrogate for multiaxial loading experiments, we determined the three-dimensional normal strain yield surface and all combinations of the two-dimensional normal-shear strain yield envelope. High-resolution finite-element models of three human femoral neck trabecular bone specimens obtained through micro-computed tomography were used. In total, 889 multiaxial-loading cases were analyzed, requiring over 41,000 CPU hours on parallel supercomputers. Our results indicated that the multiaxial yield behavior of trabecular bone in strain space was homogeneous across the specimens and nearly isotropic. Analysis of stress-strain curves along each axis in the 3-D normal strain space indicated uncoupled yield behavior, whereas substantial coupling was seen for normal-shear loading. A modified super-ellipsoid surface with only four parameters fit the normal strain yield data very well with an arithmetic error±SD less than −0.04±5.1%. Furthermore, the principal strains associated with normal-shear loading showed excellent agreement with the yield surface obtained for normal strain loading (arithmetic error±SD<2.5±6.5%). We conclude that the four-parameter “Modified Super-Ellipsoid” yield surface presented here describes the multiaxial failure behavior of human femoral neck trabecular bone very well.Keywords
This publication has 35 references indexed in Scilit:
- Effects of Bone Cement Volume and Distribution on Vertebral Stiffness After VertebroplastySpine, 2001
- Dependence of yield strain of human trabecular bone on anatomic siteJournal of Biomechanics, 2001
- Prediction of femoral fracture load using finite element models: an examination of stress- and strain-based failure theoriesJournal of Biomechanics, 2000
- Femoral strength is better predicted by finite element models than QCT and DXAJournal of Biomechanics, 1999
- Effect of local density changes on the failure load of the proximal femurJournal of Orthopaedic Research, 1999
- The effect of impact direction on the structural capacity of the proximal femur during fallsJournal of Bone and Mineral Research, 1996
- Differences between the tensile and compressive strengths of bovine tibial trabecular bone depend on modulusJournal of Biomechanics, 1994
- Fracture Prediction for the Proximal Femur Using Finite Element Models: Part II—Nonlinear AnalysisJournal of Biomechanical Engineering, 1991
- Fracture Prediction for the Proximal Femur Using Finite Element Models: Part I—Linear AnalysisJournal of Biomechanical Engineering, 1991
- Stress analysis of a condylar knee tibial component: Influence of metaphyseal shell properties and cement injection depthJournal of Orthopaedic Research, 1985