Adjusted subpixel method enables optimisation of bronchial measurements in high-resolution CT
- 1 August 2012
- journal article
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 85 (1016) , 1093-1097
Abstract
The purpose of this paper is to present a new technique of high-resolution computed tomography (HRCT) bronchial measurement, which was worked out in our centre and is based on a mathematically adjusted subpixel method (ASM). This study used a bronchial tree model comprising two polyvinyl chloride/rubber pipes with various densities placed in a larger plastic object. External and internal diameters of both pipes corresponded to the sizes of structures that are usually evaluated in HRCT scans (i.e. the bronchus with accompanying blood vessel). The model was subjected to repeated HRCT measurements of the external and internal diameters of model pipes using a subpixel technique and ASM. Significant differences were observed between mean values of external and internal diameters of model pipes determined by means of subpixel method or ASM, with the latter being the ones that resembled real diameters of the model pipes more closely. Mean external diameters of the larger and smaller model pipes determined by ASM differed from the real diameters by 0.23% and 0.57%, respectively. The internal diameter of the larger pipe was on average 25.96% larger, whereas the internal diameter of the smaller pipe was 48.05% smaller than the real diameter. The technique of non-linear prediction of HRCT bronchial measurements described in this paper raises attractive prospects in its clinical application owing to potential improvements in the objectivity and reproducibility of bronchial wall measurements.Keywords
This publication has 29 references indexed in Scilit:
- Qualitative Analysis of High-Resolution CT Scans in Severe AsthmaChest, 2009
- Inoperable brain metastases from non-small cell lung cancer: what part does whole brain radiotherapy play in standard treatment?Thorax, 2008
- Global strategy for asthma management and prevention: GINA executive summaryEuropean Respiratory Journal, 2007
- High-resolution computed tomography findings in elderly patients with asthmaEuropean Journal of Radiology, 2006
- Airway dimensions measured from micro-computed tomography and high-resolution computed tomographyEuropean Respiratory Journal, 2006
- Computed tomographic imaging of the airways: relationship to structure and functionEuropean Respiratory Journal, 2005
- Clinical Assessment of Airway Remodeling in Asthma: Utility of Computed TomographyClinical Reviews in Allergy & Immunology, 2004
- High resolution computed tomographic assessment of airway wall thickness in chronic asthma: reproducibility and relationship with lung function and severityThorax, 2002
- Difficult/therapy‐resistant asthmaThe need for an integrated approach to define clinical phenotypes, evaluate risk factors, understand pathophysiology and find novel therapiesEuropean Respiratory Journal, 1999
- CT of a Bronchial PhantomInvestigative Radiology, 1984