Understanding the dynamics of superparamagnetic particles under the influence of high field gradient arrays
Authors:
Open Access
- 24 February 2017
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 62 (6) , 2333-2360
Abstract
The aim of this study was to characterize the behaviour of superparamagnetic particles in magnetic drug targeting (MDT) schemes. A 3-dimensional mathematical model was developed, based on the analytical derivation of the trajectory of a magnetized particle suspended inside a fluid channel carrying laminar flow and in the vicinity of an external source of magnetic force. Semi-analytical expressions to quantify the proportion of captured particles, and their relative accumulation (concentration) as a function of distance along the wall of the channel were also derived. These were expressed in terms of a non-dimensional ratio of the relevant physical and physiological parameters corresponding to a given MDT protocol. The ability of the analytical model to assess magnetic targeting schemes was tested against numerical simulations of particle trajectories. The semi-analytical expressions were found to provide good first-order approximations for the performance of MDT systems in which the magnetic force is relatively constant over a large spatial range. The numerical model was then used to test the suitability of a range of different designs of permanent magnet assemblies for MDT. The results indicated that magnetic arrays that emit a strong magnetic force that varies rapidly over a confined spatial range are the most suitable for concentrating magnetic particles in a localized region. By comparison, commonly used magnet geometries such as button magnets and linear Halbach arrays result in distributions of accumulated particles that are less efficient for delivery. The trajectories predicted by the numerical model were verified experimentally by acoustically focusing magnetic microbeads flowing in a glass capillary channel, and optically tracking their path past a high field gradient Halbach array.Keywords
Funding Information
- Engineering and Physical Sciences Research Council (EP/I021795/1)
This publication has 71 references indexed in Scilit:
- Optimal Halbach permanent magnet designs for maximally pulling and pushing nanoparticlesJournal of Magnetism and Magnetic Materials, 2012
- A dynamic magnetic shift method to increase nanoparticle concentration in cancer metastases: a feasibility study using simulations on autopsy specimensInternational Journal of Nanomedicine, 2011
- The behaviors of ferromagnetic nano-particles in and around blood vessels under applied magnetic fieldsJournal of Magnetism and Magnetic Materials, 2011
- Aggregation of magnetic microparticles in the context of targeted therapies actuated by a magnetic resonance imaging systemJournal of Applied Physics, 2009
- Iron oxide nanoparticles as a drug delivery vehicle for MRI monitored magnetic targeting of brain tumorsBiomaterials, 2008
- Method of Propulsion of a Ferromagnetic Core in the Cardiovascular System Through Magnetic Gradients Generated by an MRI SystemIEEE Transactions on Biomedical Engineering, 2006
- Tomographic imaging using the nonlinear response of magnetic particlesNature, 2005
- Applications of magnetic nanoparticles in biomedicineJournal of Physics D: Applied Physics, 2003
- Magnetic nanoparticles and magnetocrystalline anisotropyNanostructured Materials, 1997
- Anomalous moment and anisotropy behavior infilmsPhysical Review B, 1996