The National Ignition Facility modular Kirkpatrick-Baez microscope
Authors:
- 10 August 2016
- journal article
- conference paper
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (11) , 11E316
Abstract
Current two-dimensional X-ray imaging at the National Ignition Facility (NIF) uses time resolved pinhole cameras with ∼10-25 μm pinholes. This method has limitations in the smallest resolvable features that can be imaged with reasonable photon statistics for inertial confinement fusion (ICF) applications. ICF sources have a broadband self-emission spectrum that causes the pinhole images obtained, through thin foil filters, to contain a similarly broadband spectrum complicating the interpretation of structure in the source. In order to study phenomena on the scale of ∼5 μm, such as dopant mix in the ICF capsule, a narrow energy band, higher spatial resolution microscope system with improved signal/noise has been developed using X-ray optics. Utilizing grazing incidence mirrors in a Kirkpatrick-Baez microscope (KBM) configuration [P. Kirkpatrick and A. V. Baez, J. Opt. Soc. Am. 38, 766–774 (1948)], an X-ray microscope has been designed and fielded on NIF with four imaging channels. The KBM has ∼12 × magnification, <8 μm resolution, and higher throughput in comparison to similar pinhole systems. The first KBM mirrors are coated with a multilayer mirror to allow a “narrow band” energy response at 10.2 keV with ΔE ∼ 3 keV. By adjusting the mirror coating only, the energy response can be matched to the future experimental requirements. Several mirror packs have been commissioned and are interchangeable in the diagnostic snout.Keywords
This publication has 20 references indexed in Scilit:
- Advances in x-ray framing cameras at the National Ignition Facility to improve quantitative precision in x-ray imagingReview of Scientific Instruments, 2016
- Investigating high speed phenomena in laser plasma interactions using dilation x-ray imager (invited)Review of Scientific Instruments, 2014
- First Measurements of Hydrodynamic Instability Growth in Indirectly Driven Implosions at Ignition-Relevant Conditions on the National Ignition FacilityPhysical Review Letters, 2014
- Dilation x-ray imager a new/faster gated x-ray imager for the NIFReview of Scientific Instruments, 2012
- Pulse-dilation enhanced gated optical imager with 5 ps resolution (invited)Review of Scientific Instruments, 2010
- Gated x-ray detector for the National Ignition FacilityReview of Scientific Instruments, 2006
- The National Ignition FacilityOptical Engineering, 2004
- The physics basis for ignition using indirect-drive targets on the National Ignition FacilityPhysics of Plasmas, 2004
- High-energy x-ray microscopy techniques for laser-fusion plasma research at the National Ignition FacilityApplied Optics, 1998
- Formation of Optical Images by X-RaysJournal of the Optical Society of America, 1948